OSHA SearchOSHA records by employer

Juan Reyes: OSHA inspections and violations

Cabot, Arkansas · Drywall and Insulation Contractors · NAICS 238310

1inspections
4citation items
$5,986current penalties
Jan 24, 2018last inspection

OSHA inspectors have visited Juan Reyes in Arkansas one time.

It opened on Jan 24, 2018 as a planned inspection, in Cabot.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $9,977; today they stand at $5,986, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Juan Reyes averages $5,986 across 1 cited inspection.

Juan Reyes: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Arkansas · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Arkansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arkansas

Checking a subcontractor, a client or your own company? Watch Juan Reyes and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342903242 OPENED JAN 24, 2018Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jul 1, 2019

1st Community Bank Bldg Construction 11 Prospect Ct, Cabot, AR 72023 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,880$2,328Mar 12, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,217$1,330Mar 12, 2018Final
Citation 1, item 3a
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$3,880$2,328Mar 12, 2018Final
Citation 1, item 3b
29 CFR 1926.451(g)(4) · Scaffolds, general requirements
Serious$0$0Mar 12, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(2)

(2) Effective September 2, 1997, the employer shall have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds. Employers are required to provide fall protection for employees erecting or dismantling supported scaffolds where the installation and use of such protection is feasible and does not create a greater hazard.

Other drywall and insulation contractors employers in Arkansas

Alert subscribers get notified of each newly cited employer in Arkansas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.