Inspection 348236183 OPENED MAY 7, 2025Closed
329 Clarkson Avenue, Brooklyn, NY 11201 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
JW Electric Corporation has 3 OSHA inspections on record in New York, the first in 2016.
OSHA's last visit started on May 7, 2025 as part of a related case, in Brooklyn.
Across those inspections OSHA issued 3 citation items: 3 serious.
OSHA proposed $21,154 in penalties. After settlements and reviews the total is $15,696, down 26%.
Most often, OSHA cited 1926.405, job-site wiring (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. JW Electric Corporation averages $7,848 over 2 cited inspections in that time.
New York · latest 90 days of OSHA records
360employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch JW Electric Corporation and get notified the morning OSHA posts a new citation for it.
Watch this company329 Clarkson Avenue, Brooklyn, NY 11201 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
54-25 101st Street, Corona, NY 11368 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(a)(1)(i) · Job-site wiring |
Serious | $3,696 | $3,696 | Aug 23, 2018 | Final |
2848 Bainbridge Avenue, Bronx, NY 10458 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(e) · Electrical equipment on job sites |
Serious | $8,729 | $6,000 | Oct 25, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring |
Serious | $8,729 | $6,000 | Oct 25, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.403(e)
(e) Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.
29 CFR 1926.405(a)(1)(i)
(1) General requirements—(i) Electrical continuity of metal raceways and enclosures. Metal raceways, cable armor, and other metal enclosures for conductors shall be metallically joined together into a continuous electric conductor and shall be so connected to all boxes, fittings, and cabinets as to provide effective electrical continuity.
29 CFR 1926.405(a)(2)(ii)(i)
(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.