OSHA SearchOSHA records by employer

JWW Home Improvement Inc.: OSHA inspections and violations

Cleveland, Ohio · Siding Contractors · NAICS 238170

2inspections
4citation items
$35,758current penalties
Jul 18, 2023last inspection

JWW Home Improvement Inc. has 2 OSHA inspections on record in Ohio, the first in 2018.

OSHA's last visit started on Jul 18, 2023 as a planned inspection, in North Olmsted.

Across those inspections OSHA issued 4 citation items: 1 serious and 3 repeat.

OSHA proposed $35,758 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. JWW Home Improvement Inc. averages $17,879 over 2 cited inspections in that time.

JWW Home Improvement Inc.: OSHA citation items per year, 2018 to 2023
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch JWW Home Improvement Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346839616 OPENED JUL 18, 2023Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jan 7, 2026

4286 Porter Road, North Olmsted, OH 44070 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$25,781$25,781Jul 21, 2023Final
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$0$0Jul 21, 2023Final

Inspection 343660411 OPENED DEC 13, 2018Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 25, 2022

9073 Baltic Rd., Cleveland, OH 44102 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,217$2,217Dec 20, 2018Final
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$7,760$7,760Dec 20, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other siding contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.