OSHA SearchOSHA records by employer

K-A Construction Services LLC: OSHA inspections and violations

Roanoke, Virginia · Framing Contractors · NAICS 238130

1inspections
5citation items
$3,759current penalties
Jun 26, 2025last inspection

OSHA has inspected K-A Construction Services LLC once in Virginia.

The inspection began on Jun 26, 2025 as a planned inspection, in Roanoke.

That inspection ended with 5 citation items: 2 serious and 3 other-than-serious.

Penalties were first proposed at $5,370 and now stand at $3,759, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and K-A Construction Services LLC averages $3,759 (1 cited inspection).

K-A Construction Services LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch K-A Construction Services LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348337452 OPENED JUN 26, 2025Closed

Planned · Complete · Safety · 3 employees at the site · Closed Sep 3, 2026

305 Mountain Ave, Roanoke, VA 24016 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$2,685$1,880Oct 7, 2025Final
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,685$1,880Oct 7, 2025Final
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Oct 7, 2025Final
Citation 2, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Oct 7, 2025Final
Citation 2, item 3
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Oct 7, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.