OSHA SearchOSHA records by employer

K & D Plumbing, Inc.: OSHA inspections and violations

Rome, Georgia · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
7citation items
$48,000current penalties
Mar 13, 2025last inspection

OSHA has inspected K & D Plumbing, Inc. 2 times in Georgia since 2023.

The latest one began on Mar 13, 2025 to follow up on an earlier case, in Silver Creek.

Those inspections ended with 7 citation items: 6 serious and 1 willful.

Penalties were first proposed at $184,387 and now stand at $48,000, 74% lower after settlements or reviews.

Excavations comes up most often in these citations: 4 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and K & D Plumbing, Inc. averages $48,000 (1 cited inspection).

1 inspection on this page followed a fatal incident.

K & D Plumbing, Inc.: OSHA citation items per year, 2023 to 2025
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch K & D Plumbing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348103433 OPENED MAR 13, 2025Closed

Follow-up · Partial · Safety · 4 employees at the site · Closed May 12, 2025

54 Daryl Road, Silver Creek, GA 30173 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346838048 OPENED JUL 12, 2023Open

Fatality or catastrophe · Complete · Safety · 4 employees at the site · Open

4203 Martha Berry Hwy, Rome, GA 30161 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 12, 2023 (fatal): Employee is killed from internal injuries in fall into manho

At 2:30 p.m. on July 12, 2023, an employee working as a journeyman plumber on a crew for a plumbing contractor had entered a manhole. The employee needed to unclog a sewage line that he and his crew were installing. The employee stood on the second step down into the manhole and attempted to reach the line opening when he lost his footing. He fell approximately 20 feet to the bottom. The employee sustained internal organ damage and died.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$4,688$2,344Jan 11, 2024Final
Citation 1, item 2
29 CFR 1926.651(h)(1) · Excavations
Serious$4,688$2,344Jan 11, 2024Final
Citation 1, item 3
29 CFR 1926.651(j)(2) · Excavations
Serious$4,688$2,344Jan 11, 2024Final
Citation 1, item 4
29 CFR 1926.651(k)(1) · Excavations
Serious$4,688$2,344Jan 11, 2024Final
Citation 1, item 5
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,688$2,344Jan 11, 2024Final
Citation 1, item 6
29 CFR 1926.1204(e)(1)(i) · Permit-required confined space program
Serious$4,688$2,344Jan 11, 2024Final
Citation 2, item 1
29 CFR 1926.1203(d) · Confined Spaces in Construction: general requirements
Willful$156,259$33,936Jan 11, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.1203(d)

(d) If any employer decides that employees it directs will enter a permit space, that employer must have a written permit space program that complies with § 1926.1204 implemented at the construction site. The written program must be made available prior to and during entry operations for inspection by employees and their authorized representatives.

29 CFR 1926.1204 · Permit-required confined space program

29 CFR 1926.1204(e)(1)(i)

(i) Perform pre-entry testing to the extent feasible before entry is authorized; and,

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

Other plumbing, heating, and air-conditioning contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.