OSHA SearchOSHA records by employer

K & M Concrete, Inc.: OSHA inspections and violations

Fort Myers, Florida · Industrial Building Construction · NAICS 236210

1inspections
3citation items
$7,200current penalties
Jul 7, 2016last inspection

OSHA inspectors have visited K & M Concrete, Inc. in Florida one time.

It opened on Jul 7, 2016 as a planned inspection, in Fort Myers.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $7,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. K & M Concrete, Inc. averages $7,200 across 1 cited inspection.

K & M Concrete, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch K & M Concrete, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341605459 OPENED JUL 7, 2016Closed

Planned · Partial · Safety · 15 employees at the site · Closed Jan 20, 2017

14607 Ben C Pratt Pkwy, Fort Myers, FL 33912 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$2,800Jul 22, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$2,800Jul 22, 2016Final
Citation 1, item 3
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$1,600$1,600Jul 22, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.451(h)(2)(ii)

(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;

Other industrial building construction employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.