OSHA SearchOSHA records by employer

K Construction, LLC: OSHA inspections and violations

Corinth, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$24,376current penalties
May 1, 2023last inspection

OSHA has inspected K Construction, LLC once in Texas.

The inspection began on May 1, 2023 as a planned inspection, in Corinth.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $40,627 and now stand at $24,376, 40% lower after settlements or reviews.

Excavations comes up most often in these citations: 3 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and K Construction, LLC averages $24,376 (1 cited inspection).

K Construction, LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites K Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346670797 OPENED MAY 1, 2023Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jun 16, 2023

Intersection Of Parkridge Drive And Lake Sharon Drive, Corinth, TX 76210 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$10,938$6,563Jun 1, 2023Final
Citation 1, item 2
29 CFR 1926.651(h)(1) · Excavations
Serious$7,813$4,688Jun 1, 2023Final
Citation 1, item 3
29 CFR 1926.651(j)(2) · Excavations
Serious$10,938$6,563Jun 1, 2023Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$10,938$6,563Jun 1, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(h)(1)

(h) Protection from hazards associated with water accumulation. (1) Employees shall not work in excavations in which there is accumulated water, or in excavations in which water is accumulating, unless adequate precautions have been taken to protect employees against the hazards posed by water accumulation. The precautions necessary to protect employees adequately vary with each situation, but could include special support or shield systems to protect from cave-ins, water removal to control the level of accumulating water, or use of a safety harness and lifeline.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.