OSHA SearchOSHA records by employer

K S a Landscaping Inc.: OSHA inspections and violations

Perry Hall, Maryland · Masonry Contractors · NAICS 238140

1inspections
3citation items
$547current penalties
Oct 18, 2016last inspection

OSHA has inspected K S a Landscaping Inc. once in Maryland.

The inspection began on Oct 18, 2016 as a planned inspection, in Perry Hall.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $1,350 and now stand at $547, 59% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and K S a Landscaping Inc. averages $547 (1 cited inspection).

K S a Landscaping Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

185employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch K S a Landscaping Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341846749 OPENED OCT 18, 2016Closed

Planned · Complete · Safety · 3 employees at the site · Closed Feb 22, 2017

9602 Wickstead Court, Perry Hall, MD 21128 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$450$225Jan 10, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$450$225Jan 10, 2017Final
Citation 1, item 3
29 CFR 1926.1052(c)(4) · Stairways in construction
Serious$450$97Jan 10, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(4)

(4) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members, shall be provided between the top rail of the stairrail system and the stairway steps.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.