OSHA SearchOSHA records by employer

K2 Electrical, LLC.: OSHA inspections and violations

North Bergen, New Jersey · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
2citation items
$1,542current penalties
Dec 10, 2019last inspection

OSHA inspectors have visited K2 Electrical, LLC. in New Jersey one time.

It opened on Dec 10, 2019 as part of a related case, in North Bergen and is still open.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $6,168; today they stand at $1,542, 75% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. K2 Electrical, LLC. averages $1,542 across 1 cited inspection.

K2 Electrical, LLC.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch K2 Electrical, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344504097 OPENED DEC 10, 2019Open

Unprogrammed related · Partial · Safety · 5 employees at the site · Open

1706 Paterson Plank Road, North Bergen, NJ 07047 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$3,084$1,542Apr 14, 2020Final
Citation 1, item 2b
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$3,084$0Apr 14, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other electrical contractors and other wiring installation contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.