OSHA SearchOSHA records by employer

Kaines West Michigan Co: OSHA inspections and violations

Ludington, Michigan · Other Fabricated Wire Product Manufacturing · NAICS 332618

16inspections
110citation items
$43,256current penalties
Jun 20, 2017last inspection

Since 1990, OSHA inspectors have visited Kaines West Michigan Co in Michigan 16 times.

The most recent inspection opened on Jun 20, 2017 on a referral, in Ludington.

In all, OSHA issued 110 citation items: 57 serious, 10 repeat and 43 other-than-serious.

The proposed penalties came to $67,050; today they stand at $43,256, 35% less.

The rule cited most here is 4081.34 (), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Kaines West Michigan Co averages $4,950 across 2 cited inspections.

Kaines West Michigan Co also files yearly injury logs with OSHA, summarized below.

Kaines West Michigan Co: OSHA citation items per year, 1990 to 2017
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

609employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Kaines West Michigan Co and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342394772 OPENED JUN 20, 2017Closed

Referral · Partial · Safety · 77 employees at the site · Closed Dec 19, 2017

211 E Dowland St, Ludington, MI 49431 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on May 19, 2017: Employee amputates fingertip in a nip point

At 7:40 a.m. on May 19, 2017, an employee was operating a welding press. The employee leaned forward with their foot on the foot control and caught their finger in a nip point. The employee amputated the tip of their right index finger.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.11282(4)
Repeat$8,400$8,400Oct 19, 2017Final

Inspection 340189117 OPENED AUG 3, 2016Closed

Planned · Partial · Safety · 77 employees at the site · Closed Jan 6, 2017

211 Dowland St., Ludington, MI 49431 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.11282(4)
Serious$1,500$1,500Dec 16, 2016Final

Inspection 315373670 OPENED MAY 1, 2014Closed

Planned · Partial · Safety · 98 employees at the site · Closed Sep 11, 2014

211 E Dowland, Ludington, MI 49431 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,500$1,250Sep 3, 2014Closed

Inspection 315373746 OPENED MAY 1, 2014Closed

Planned · Complete · Safety · 98 employees at the site · Closed Sep 11, 2014

211 E Dowland, Ludington, MI 49431 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,500$1,250Sep 3, 2014Closed
Citation 1, item 2 Serious$2,500$1,250Sep 3, 2014Closed
Citation 1, item 3 Serious$1,400$700Sep 3, 2014Closed
Citation 1, item 4a Serious$2,500$1,250Sep 3, 2014Closed
Citation 1, item 4b Serious$0$0Sep 3, 2014Closed
Citation 2, item 1a Other-than-serious$0$0Sep 3, 2014Closed
Citation 2, item 1b Other-than-serious$0$0Sep 3, 2014Closed
Citation 2, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 3, 2014Closed
Citation 2, item 2b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Sep 3, 2014Closed

Inspection 311985170 OPENED JUN 15, 2009Closed

Unprogrammed other · Partial · Safety · 70 employees at the site · Closed Aug 13, 2009

211 E Dowland, Ludington, MI 49431 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,400$560Jul 20, 2009Closed

Inspection 311985188 OPENED JUN 15, 2009Closed

Planned · Complete · Safety · 70 employees at the site · Closed Sep 28, 2009

211 E Dowland, Ludington, MI 49431 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$800$320Jul 20, 2009Closed
Citation 1, item 2 Serious$800$320Jul 20, 2009Closed
Citation 1, item 3 Serious$800$320Jul 20, 2009Closed
Citation 1, item 4 Serious$800$320Jul 20, 2009Closed
Citation 1, item 5 Serious$800$320Jul 20, 2009Closed
Citation 1, item 6 Serious$800$320Jul 20, 2009Closed
Citation 1, item 7 Serious$800$320Jul 20, 2009Closed
Citation 1, item 8 Serious$800$320Jul 20, 2009Closed
Citation 1, item 9 Serious$800$320Jul 20, 2009Closed
Citation 1, item 10 Serious$800$320Jul 20, 2009Closed
Citation 1, item 11
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$800$320Jul 20, 2009Closed
Citation 2, item 1 Repeat$1,600$640Jul 20, 2009Closed
Citation 3, item 1 Other-than-serious$0$0Jul 20, 2009Closed
Citation 3, item 2 Other-than-serious$0$0Jul 20, 2009Closed
Citation 3, item 3 Other-than-serious$0$0Jul 20, 2009Closed
Citation 3, item 4 Other-than-serious$0$0Jul 20, 2009Closed
Citation 3, item 5 Other-than-serious$0$0Jul 20, 2009Closed
Citation 3, item 6
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Jul 20, 2009Closed
Citation 3, item 7
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jul 20, 2009Closed
Citation 3, item 8 Other-than-serious$400$160Jul 20, 2009Closed
Citation 4, item 1 Repeat$160$64Jul 20, 2009Closed

Inspection 308842418 OPENED JAN 18, 2007Closed

Planned · Complete · Safety · 55 employees at the site · Closed Apr 4, 2007

211 E Dowland, Ludington, MI 49431 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$700$350Mar 12, 2007Closed
Citation 1, item 2 Serious$700$350Mar 12, 2007Closed
Citation 1, item 3 Serious$700$350Mar 12, 2007Closed
Citation 1, item 4 Serious$700$350Mar 12, 2007Closed
Citation 1, item 5 Serious$700$350Mar 12, 2007Closed
Citation 1, item 6 Serious$700$350Mar 12, 2007Closed
Citation 1, item 7
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$700$350Mar 12, 2007Closed
Citation 2, item 1 Other-than-serious$0$0Mar 12, 2007Closed
Citation 2, item 2 Other-than-serious$0$0Mar 12, 2007Closed
Citation 2, item 3 Other-than-serious$0$0Mar 12, 2007Closed
Citation 2, item 4 Other-than-serious$0$0Mar 12, 2007Closed
Citation 2, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Mar 12, 2007Closed
Citation 2, item 6
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Mar 12, 2007Closed
Citation 2, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 12, 2007Closed

Inspection 127246569 OPENED JUL 25, 2000Closed

Follow-up · Partial · Safety · 67 employees at the site · Closed Aug 15, 2000

211 E Dowland, Ludington, MI 49431 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

8 older inspections

Inspection 127149599 OPENED JUL 8, 1999Closed

Planned · Partial · Safety · 60 employees at the site · Closed Nov 29, 1999

211 E Dowland, Ludington, MI 49431 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$400$200Oct 8, 1999Closed

Inspection 124978487 OPENED JAN 2, 1996Closed

Planned · Complete · Safety · 70 employees at the site · Closed Aug 15, 2000

211 E Dowland, Ludington, MI 49431 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$750$637Feb 7, 1996Final
Citation 1, item 2 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 3 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 4 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 5 Serious$750$637Feb 7, 1996Final
Citation 1, item 6 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 7 Serious$1,000$0Feb 7, 1996Final
Citation 1, item 8 Serious$750$637Feb 7, 1996Final
Citation 1, item 9 Serious$750$0Feb 7, 1996Final
Citation 1, item 10 Serious$750$637Feb 7, 1996Final
Citation 1, item 11 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 12 Serious$1,000$0Feb 7, 1996Final
Citation 1, item 13 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 14 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 15 Serious$1,000$850Feb 7, 1996Final
Citation 1, item 16 Serious$750$637Feb 7, 1996Final
Citation 1, item 17 Serious$750$0Feb 7, 1996Final
Citation 1, item 18 Serious$750$0Feb 7, 1996Final
Citation 1, item 19
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,000$850Feb 7, 1996Final
Citation 1, item 20
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$1,000$0Feb 7, 1996Final
Citation 1, item 21
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$750$0Feb 7, 1996Final
Citation 1, item 22
29 CFR 1910.1200(h) · Hazard communication
Serious$750$637Feb 7, 1996Final
Citation 2, item 1 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 2 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 3 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 4 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 5 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 6 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 7 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 8 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 9 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 10 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 11 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 12 Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 13
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 14
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 15
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Other-than-serious$0$0Feb 7, 1996Closed
Citation 2, item 16
29 CFR 1910.1200(f)(5) · Hazard communication
Other-than-serious$0$0Feb 7, 1996Closed

Inspection 114925183 OPENED DEC 16, 1991Closed

Planned · Complete · Safety · 72 employees at the site · Closed Jul 10, 1992

211 E Dowland, Ludington, MI 49431 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$400$400Jan 21, 1992Closed
Citation 1, item 2 Serious$400$400Jan 21, 1992Closed
Citation 2, item 1 Other-than-serious$0$0Jan 21, 1992Closed
Citation 2, item 2 Other-than-serious$0$0Jan 21, 1992Closed
Citation 3, item 1 Repeat$320$320Jan 21, 1992Closed

Inspection 110691755 OPENED MAY 16, 1991Closed

Follow-up · Partial · Safety · 75 employees at the site · Closed Jun 4, 1991

211 E Dowland, Ludington, MI 49431 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110766110 OPENED SEP 24, 1990Closed

Planned · No inspection · Safety · 69 employees at the site · Closed Oct 23, 1990

211 E Dowland, Ludington, MI 49431 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110799913 OPENED AUG 20, 1990Closed

Complaint · Complete · Safety · 69 employees at the site · Closed Oct 29, 1991

211 E Dowland, Ludington, MI 49431 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$270$270Oct 4, 1990Closed
Citation 1, item 2 Serious$270$270Oct 4, 1990Closed
Citation 1, item 9 Serious$270$270Oct 4, 1990Closed
Citation 1, item 10 Serious$270$270Oct 4, 1990Closed
Citation 1, item 11 Serious$0$0Oct 4, 1990Closed
Citation 1, item 12 Serious$180$180Oct 4, 1990Closed
Citation 1, item 19 Serious$270$270Oct 4, 1990Closed
Citation 2, item 1 Repeat$1,080$1,080Oct 4, 1990Closed
Citation 2, item 2 Repeat$1,440$1,440Oct 4, 1990Closed
Citation 2, item 3 Repeat$720$720Oct 4, 1990Closed
Citation 2, item 4 Repeat$1,080$1,080Oct 4, 1990Closed
Citation 3, item 1 Other-than-serious$0$0Oct 4, 1990Closed
Citation 3, item 2 Other-than-serious$0$0Oct 4, 1990Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Ludington site logged 4 recordable injuries or illnesses among about 66 workers: 23.5 per 100 full-time workers, against a median of 3.3 for its industry. Those cases cost 1 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Kaines West Michigan Co
Ludington · 2022
66 4123.53.3

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(5)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 4080.1011

29 CFR 4080.1014

29 CFR 4081.11

29 CFR 4081.114

29 CFR 4081.1211

29 CFR 4081.1222

29 CFR 4081.1223

29 CFR 4081.125

29 CFR 4081.1281

29 CFR 4081.1282

29 CFR 4081.15

29 CFR 4081.1854

29 CFR 4081.1872

29 CFR 4081.2131

29 CFR 4081.2154

29 CFR 4081.2161

29 CFR 4081.2163

29 CFR 4081.2165

29 CFR 4081.2171

29 CFR 4081.221

29 CFR 4081.2412

29 CFR 4081.2424

29 CFR 4081.2431

29 CFR 4081.2432

29 CFR 4081.2442

29 CFR 4081.2461

29 CFR 4081.2462

29 CFR 4081.2463

29 CFR 4081.2477

29 CFR 4081.2612

29 CFR 4081.2631

29 CFR 4081.2635

29 CFR 4081.2638

29 CFR 4081.2646

29 CFR 4081.2730

29 CFR 4081.33

29 CFR 4081.3308

29 CFR 4081.3312

29 CFR 4081.3378

29 CFR 4081.34

29 CFR 4081.36

29 CFR 4081.4002

29 CFR 4081.512

29 CFR 4081.513

29 CFR 4081.632

29 CFR 4081.685

29 CFR 4081.711

29 CFR 4081.722

29 CFR 4081.727

29 CFR 4081.731

29 CFR 4081.835

29 CFR 4082.2109

29 CFR 4082.2111

Other other fabricated wire product manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.