OSHA SearchOSHA records by employer

Kaizen Auto Care, LLC: OSHA inspections and violations

Brighton, Colorado · General Automotive Repair · NAICS 811111

1inspections
3citation items
$15,604current penalties
Mar 3, 2025last inspection

OSHA has inspected Kaizen Auto Care, LLC once in Colorado.

The inspection began on Mar 3, 2025 after a complaint, in Brighton.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $26,007 and now stand at $15,604, 40% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 2 items under 1910.134.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Kaizen Auto Care, LLC averages $15,604 (1 cited inspection).

Kaizen Auto Care, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

130employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Kaizen Auto Care, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348076548 OPENED MAR 3, 2025Closed

Complaint · Partial · Health · 10 employees at the site · Closed Sep 24, 2025

109 West Walnut Street, Brighton, CO 80601 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Other-than-serious$16,550$9,930Aug 4, 2025Final
Citation 1, item 3a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$9,457$5,674Aug 4, 2025Final
Citation 1, item 3b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Aug 4, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.