OSHA SearchOSHA records by employer

Karl Manufacturing Company, Incorporated: OSHA inspections and violations

Baltimore, Maryland · Machine Shops · NAICS 332710

2inspections
26citation items
$1,184current penalties
Dec 12, 2022last inspection

OSHA has inspected Karl Manufacturing Company, Incorporated 2 times in Maryland since 1994.

The latest one began on Dec 12, 2022 as a planned inspection, in Rosedale.

Those inspections ended with 26 citation items: 3 serious and 23 other-than-serious.

Penalties were first proposed at $2,012 and now stand at $1,184, 41% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 6 items under 1910.1200.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Karl Manufacturing Company, Incorporated averages $972 (1 cited inspection).

Karl Manufacturing Company, Incorporated: OSHA citation items per year, 1994 to 2022
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

180employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Karl Manufacturing Company, Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346384282 OPENED DEC 12, 2022Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 22, 2023

8031 Philadelphia Road, Rosedale, MD 21237 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$900$486Mar 14, 2023Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$900$486Mar 14, 2023Final
Citation 2, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 3
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 4
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 5
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 6
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 7
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 8
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 10
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 11
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Mar 14, 2023Final
Citation 2, item 12
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Mar 14, 2023Final

Inspection 119599454 OPENED JUN 24, 1994Closed

Planned · Complete · Safety · 11 employees at the site · Closed Sep 23, 1994

8031 Philadelphia Rd, Baltimore, MD 21237 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$125$125Aug 22, 1994Closed
Citation 2, item 1 Other-than-serious$87$87Aug 22, 1994Closed
Citation 2, item 2
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 5
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 6
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 8
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 9
29 CFR 50405 B01
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 10
29 CFR 50406 A01
Other-than-serious$0$0Aug 22, 1994Closed
Citation 2, item 11 Other-than-serious$0$0Aug 22, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.2002

29 CFR 0912.2102

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

Other machine shops employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.