Inspection 348951674 OPENED MAY 21, 2026Closed
280 E Palmetto Park Rd, Boca Raton, FL 33432 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Boca Raton, Florida · Commercial and Institutional Building Construction · NAICS 236220
OSHA has inspected Kaufman LYNN Construction, Inc. 12 times in Florida since 2015.
The latest one began on May 21, 2026, in Boca Raton.
Those inspections ended with 2 citation items: 2 serious.
Penalties were first proposed at $10,140 and now stand at $6,084, 40% lower after settlements or reviews.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Kaufman LYNN Construction, Inc. averages $6,084 (1 cited inspection).
Florida · latest 90 days of OSHA records
321employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Kaufman LYNN Construction, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company280 E Palmetto Park Rd, Boca Raton, FL 33432 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
19640 W Dixie Hwy, Aventura, FL 33180 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8552 Collier Blvd Fiori Apartments, Naples, FL 34114 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1650 Ne 124th Street, North Miami, FL 33181 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1434 Sw 2nd St, Cape Coral, FL 33991 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
15560 Render Way, Nokomis, FL 34275 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1218 Sw 5th Ave., Gainesville, FL 32601 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3040-3060 Ne 6th Avenue, Oakland Park, FL 33334 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
501 Se 1 Avenue, Hallandale Beach, FL 33009 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4850 T-rex Avenue Suite 300, Boca Raton, FL 33431 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $6,338 | $3,803 | Apr 25, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(16) · Ladders in construction |
Serious | $3,802 | $2,281 | Apr 25, 2017 | Final |
2301 N. 29th Avenue, Hollywood, FL 33020 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1224 Ne 24th St, Wilton Manors, FL 33305 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(16)
(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.
29 CFR 1926.501(b)(10)
(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.