OSHA SearchOSHA records by employer

Kautz Construction Co.: OSHA inspections and violations

Wormleysburg, Pennsylvania · Roofing Contractors · NAICS 238160

8inspections
15citation items
$56,239current penalties
Aug 15, 2025last inspection

OSHA has inspected Kautz Construction Co. 8 times in Pennsylvania since 2008.

The latest one began on Aug 15, 2025 after a fatality or catastrophe, in West Hazleton; the case is still open.

Those inspections ended with 15 citation items: 14 serious and 1 other-than-serious.

Penalties were first proposed at $71,660 and now stand at $56,239, 22% lower after settlements or reviews.

Fall protection training in construction comes up most often in these citations: 4 items under 1926.503.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Kautz Construction Co. averages $11,154 (5 cited inspections).

It reported 1 severe injury to OSHA since 2015.

Kautz Construction Co.: OSHA citation items per year, 2008 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Kautz Construction Co. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348443201 OPENED AUG 15, 2025Open

Fatality or catastrophe · Complete · Safety · 9 employees at the site · Open

25 Jaycee Dr., West Hazleton, PA 18202 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$16,550$12,500Jan 28, 2026Final
Citation 1, item 1b
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$0$0Jan 28, 2026Final
Citation 1, item 2a
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$16,550$12,500Jan 28, 2026Final
Citation 1, item 2b
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$0$0Jan 28, 2026Final

Inspection 348173709 OPENED APR 9, 2025Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Sep 26, 2025

650 Red Bone Rd, Chester Springs, PA 19425 · Roofing, Siding, and Insulation Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344913124 OPENED SEP 3, 2020Closed

Referral · Partial · Safety · 30 employees at the site · Closed Mar 18, 2021

900 S. York Road, Willow Grove, PA 19090 · Roofing, Siding, and Insulation Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Incident on Sep 1, 2020: Employee incurs electric shock and burns when lift comes int

At 12:30 p.m. on September 1, 2020, an employee was working for a roofing contractor. He was a roofer. The firm's workers were at a construction project on a commercial building. The firm was working at an automotive dealership that sold new and used cars. It was raining. The employee was operating a Skyjack model number SJ61T aerial lift. He was wearing a hardhat, a harness, a lanyard, and safety glasses. There was an overhead power line next to the roof. It had not been deenergized or grounded. One account suggested that the lines were energized at somewhere between 200 kilovolts (kV) to 350K kV. The employee was bringing down trash from the roof to throw into a dumpster. He was lowering the lift's arm from the 30-foot (9.1-meter) roof and swung it over to the dumpster, located under the power lines. By one account, the lift struck an energized conductor. An electric current arced from the phase conductor and entered the employee's right wrist. By another account, the employee struck the line and received electrical burns to his face and hands. In any event, the employee suffered an electric shock and electrical burns. He was hospitalized. There was no spotter on the ground directing the employee while he was operating near the lines. When fully extended, the boom height was 61 feet (18.6 meters). The operator's manual stated that the lift was not insulated and that personnel should maintain a safe approach distance from power lines. It referenced the distance, the ANSI standard, and the OSHA standard. The manual provided a chart for safe approach distance by voltage in the electrical lines. The chart showed a safe approach distance of 20 feet (6.1 meters) for lines energized at 200 kV to 350 kV.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$9,557$6,707Feb 3, 2021Final
Citation 1, item 2
29 CFR 1926.454(a)(1) · Scaffold training
Serious$9,557$6,707Feb 3, 2021Final

Inspection 342368321 OPENED JUN 1, 2017Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jul 13, 2017

10 South Prince Street, Lancaster, PA 17603 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$2,390$2,390Jun 23, 2017Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$11,154$10,163Jun 23, 2017Final
Citation 3, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$447$447Jun 23, 2017Final

Inspection 340780303 OPENED JUL 2, 2015Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Oct 5, 2015

1861 Catasauqua Rd, Bethlehem, PA 18017 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,080$3,080Sep 3, 2015Final

Inspection 340561638 OPENED APR 15, 2015Closed

Programmed other · Partial · Safety · 2 employees at the site · Closed Jun 22, 2015

Notre Dame Of Bethlehem School Catholic Elementary School 1861 Catasauqua Road, Bethlehem, PA 18018 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$1,700$1,275Apr 23, 2015Final
Citation 1, item 1b
29 CFR 1926.503(a)(2)(ii) · Fall protection training in construction
Serious$0$0Apr 23, 2015Final

Inspection 310842992 OPENED MAR 5, 2008Closed

Referral · Partial · Safety · 5 employees at the site · Closed Apr 8, 2008

401 South Front Street, Wormleysburg, PA 17043 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$375$260Mar 19, 2008Closed

Inspection 310842687 OPENED FEB 25, 2008Closed

Referral · Partial · Safety · 3 employees at the site · Closed Apr 8, 2008

401 South Front Street, Wormleysburg, PA 17043 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$300$210Feb 28, 2008Closed
Citation 1, item 1b Serious$0$0Feb 28, 2008Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Sep 1, 2020, Willow Grove: Hospitalization · electrical burns, unspecified · hand(s), unspecified

While working from an aerial lift, an employee came into contact with an overhead energized line. The employee was shocked and suffered a burn to the hand.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.