Inspection 343394557 OPENED AUG 15, 2018Closed
13745 Philbin Rd, Pocatello, ID 83202 · Regulation, Licensing, and Inspection of Miscellaneous Commercial Sectors · OSHA's record · Phone and website on Google Maps
Incident on Aug 14, 2018: Employee is burned in fuel tanker truck explosion
At 10:00 p.m. on August 14, 2018, Employee #1 incurred burns when a tank exploded due to residual diesel vapor. The employee was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1910.252(c)(1)(iv) · Welding fire safety |
Serious | $0 | $2,900 | Jan 31, 2019 | Final |
| Citation 1, item 1c 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $0 | $0 | Jan 31, 2019 | Final |
| Citation 1, item 2b 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $0 | $3,500 | Jan 31, 2019 | Final |
| Citation 1, item 2c 29 CFR 1910.146(c)(4) · Permit-required confined spaces |
Serious | $0 | $0 | Jan 31, 2019 | Final |
| Citation 1, item 2d 29 CFR 1910.146(c)(5)(ii)(c) · Permit-required confined spaces |
Serious | $0 | $0 | Jan 31, 2019 | Final |
| Citation 1, item 2e 29 CFR 1910.146(c)(5)(ii)(h) · Permit-required confined spaces |
Serious | $0 | $0 | Jan 31, 2019 | Final |
| Citation 1, item 2f 29 CFR 1910.146(e)(1) · Permit-required confined spaces |
Serious | $0 | $0 | Jan 31, 2019 | Final |
| Citation 1, item 2g 29 CFR 1910.146(g)(1) · Permit-required confined spaces |
Serious | $0 | $0 | Jan 31, 2019 | Final |
| Citation 1, item 3a 29 CFR 1910.252(a)(3)(i) · Welding fire safety |
Serious | $3,978 | $3,978 | Jan 31, 2019 | Final |
| Citation 1, item 3b 29 CFR 1910.252(a)(3)(ii) · Welding fire safety |
Serious | $0 | $0 | Jan 31, 2019 | Final |
| Citation 1, item 4a 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $2,273 | $2,273 | Jan 31, 2019 | Final |
| Citation 1, item 4b 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Serious | $0 | $0 | Jan 31, 2019 | Final |