OSHA SearchOSHA records by employer

KD Atkee Construction: OSHA inspections and violations

North Logan, Utah · Flooring Contractors · NAICS 238330

1inspections
2citation items
$1,275current penalties
Oct 26, 2015last inspection

OSHA inspectors have visited KD Atkee Construction in Utah one time.

It opened on Oct 26, 2015 as a planned inspection, in North Logan.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $2,550; today they stand at $1,275, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. KD Atkee Construction averages $1,275 across 1 cited inspection.

KD Atkee Construction: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch KD Atkee Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341017580 OPENED OCT 26, 2015Closed

Planned · Partial · Safety · 2 employees at the site · Closed Dec 18, 2015

347 E 2280 N Bldg 347b, North Logan, UT 84341 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$1,500$750Nov 16, 2015Final
Citation 1, item 2
29 CFR 1926.405(g)(2) · Job-site wiring
Serious$1,050$525Nov 16, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.405 · Job-site wiring

Other flooring contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.