KDM Electric LLC: OSHA inspections and violations

Alexandria, Louisiana · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
4citation items
$0current penalties
Jul 19, 2017last inspection

KDM Electric LLC has 4 OSHA inspections on record in Louisiana, the first in 1986.

OSHA's last visit started on Jul 19, 2017, in Libuse.

Across those inspections OSHA issued 4 citation items: 4 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1926.405, job-site wiring (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. KDM Electric LLC averages $0 over 1 cited inspection in that time.

KDM Electric LLC: OSHA citation items per year, 1986 to 2017
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

19employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch KDM Electric LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342504917 OPENED JUL 19, 2017Closed

Unprogrammed other · Partial · Safety · 11 employees at the site · Closed Sep 25, 2017

La Highway 28, Libuse, LA 71348 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Aug 11, 2017Final

Inspection 313028797 OPENED JAN 25, 2010Closed

Planned · Partial · Safety · 32 employees at the site · Closed Feb 26, 2010

Building 1007, F Street, Camp Beauregard, LA 71301 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Feb 21, 2010Closed

Inspection 311524870 OPENED JUN 18, 2008Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 30, 2009

Hwy 84 & 9th St, Jena, LA 71342 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Jul 24, 2008Closed
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Jul 24, 2008Closed

Inspection 1381482 OPENED SEP 17, 1986Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 23, 1986

4051 Bayou Rapides, Alexandria, LA 70301 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

Other electrical contractors and other wiring installation contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.