OSHA SearchOSHA records by employer

Keeco, LLC: OSHA inspections and violations

Dallas, Texas · Curtain and Linen Mills · NAICS 314120

3inspections
3citation items
$40,473current penalties
Sep 9, 2025last inspection

Keeco, LLC has 3 OSHA inspections on record in Texas, the first in 2004.

OSHA's last visit started on Sep 9, 2025 to follow up on an earlier case, in Dallas.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $47,473 in penalties. After settlements and reviews the total is $40,473, down 15%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,872. Keeco, LLC averages $40,473 over 1 cited inspection in that time.

Keeco, LLC also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Keeco, LLC: OSHA citation items per year, 2004 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Keeco, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348494063 OPENED SEP 9, 2025Closed

Follow-up · Partial · Safety · 425 employees at the site · Closed Feb 6, 2026

5450 West Kiest Boulevard, Dallas, TX 75236 · Curtain and Linen Mills · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347258709 OPENED FEB 5, 2024Closed

Referral · Partial · Safety · 350 employees at the site · Closed Jun 18, 2024

5450 West Kiest Boulevard, Dallas, TX 75236 · Curtain and Linen Mills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$15,211$13,211May 10, 2024Final
Citation 1, item 3
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Serious$16,131$13,631May 10, 2024Final
Citation 1, item 4
29 CFR 1910.333(c)(2) · Working near live electrical parts
Serious$16,131$13,631May 10, 2024Final

Inspection 306569997 OPENED JUL 12, 2004Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Jul 12, 2004

151 Brown Rd, Dayton, TX 77335 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Dallas site logged 4 recordable injuries or illnesses among about 225 workers: 1.8 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 119 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Keeco, LLC - Dallas
Dallas · 2024
225 411.81.9
Keeco Texas
Dallas · 2022
138 332.11.9

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 30, 2024, Dallas: Hospitalization · other multiple traumatic injuries n.e.c. · hand(s), finger(s) unspecified

An employee was operating a textile processing machine. Fill material was protruding from the feed rollers under the machine; the employee was trying to pull it out when the machine activated and began to pull it back into the feed rollers. The employee's right hand was broken, lacerated, and partially degloved.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(e)(1)(ii)

(ii) Other markings giving voltage, current, wattage, or other ratings as necessary.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(2)

(2) Work on energized equipment. Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.

Other curtain and linen mills employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.