OSHA SearchOSHA records by employer

Keith Brown Drywall, Inc.: OSHA inspections and violations

Ukiah, California · Drywall and Insulation Contractors · NAICS 238310

6inspections
7citation items
$6,185current penalties
Aug 31, 2022last inspection

Keith Brown Drywall, Inc. has 6 OSHA inspections on record in California, the first in 2009.

OSHA's last visit started on Aug 31, 2022 to follow up on an earlier case, in Gridley.

Across those inspections OSHA issued 7 citation items: 2 serious and 5 other-than-serious.

OSHA proposed $8,484 in penalties. After settlements and reviews the total is $6,185, down 27%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Keith Brown Drywall, Inc. averages $2,062 over 3 cited inspections in that time.

Keith Brown Drywall, Inc.: OSHA citation items per year, 2009 to 2022
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,130employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Keith Brown Drywall, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346184344 OPENED AUG 31, 2022Closed

Follow-up · Partial · Safety · 15 employees at the site · Closed May 25, 2023

655 E Gridley Road, Gridley, CA 95948 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1509(C)
Other-than-serious$185$185Sep 2, 2022Final
Citation 1, item 2
29 CFR 3395(I)
Other-than-serious$185$185Sep 2, 2022Final

Inspection 345729081 OPENED JAN 14, 2022Closed

Referral · Partial · Health · 2 employees at the site · Closed Apr 6, 2022

680 Oro Dam Blvd, Oroville, CA 95965 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344393285 OPENED OCT 16, 2019Closed

Unprogrammed other · Partial · Safety · 40 employees at the site · Closed Nov 26, 2019

Bldg. 24-25 B Welcome Center, Beale Afb, CA 95903 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2)(ii) · Scaffolds, general requirements
Serious$4,790$3,353Nov 5, 2019Final
Citation 1, item 2
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,874$2,012Nov 5, 2019Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$0$0Nov 5, 2019Final

Inspection 343515797 OPENED OCT 3, 2018Closed

Referral · Partial · Safety · 12 employees at the site · Closed Oct 19, 2018

2801 Notre Dame Blvd, Chico, CA 95928 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1512(B)
Other-than-serious$225$225Oct 8, 2018Final
Citation 1, item 2
29 CFR 3395(I)
Other-than-serious$225$225Oct 8, 2018Final

Inspection 340281229 OPENED NOV 20, 2014Closed

Planned · Partial · Safety · 20 employees at the site · Closed Feb 6, 2015

612 E Kettelman Ln, Lodi, CA 95241 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125475269 OPENED JUN 18, 2009Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Nov 23, 2009

437 N Orchard Ave, Ukiah, CA 95482 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)(ii)

(ii) Where scaffolds must be used in areas that the employer can demonstrate are so narrow that platforms and walkways cannot be at least 18 inches (46 cm) wide, such platforms and walkways shall be as wide as feasible, and employees on those platforms and walkways shall be protected from fall hazards by the use of guardrails and/or personal fall arrest systems.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other drywall and insulation contractors employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.