OSHA SearchOSHA records by employer

Kemar, Inc: OSHA inspections and violations

Harrisburg, Pennsylvania · Residential Remodelers · NAICS 236118

3inspections
12citation items
$16,285current penalties
Aug 8, 2018last inspection

OSHA has inspected Kemar, Inc 3 times in Pennsylvania since 2004.

The latest one began on Aug 8, 2018 on a referral, in Harrisburg.

Those inspections ended with 12 citation items: 11 serious and 1 other-than-serious.

Penalties were first proposed at $18,685 and now stand at $16,285, 13% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 11 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Kemar, Inc averages $1,885 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Kemar, Inc: OSHA citation items per year, 2004 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

300employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Kemar, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343370359 OPENED AUG 8, 2018Closed

Referral · Partial · Health · 3 employees at the site · Closed Jul 25, 2019

224 South 20th Street, Harrisburg, PA 17104 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.62(d)(1)(i) · Lead in construction
Other-than-serious$1,885$1,885Sep 21, 2018Final

Inspection 315886945 OPENED DEC 28, 2011Closed

Programmed other · Partial · Safety · 4 employees at the site · Closed Feb 7, 2014

2286 North 6th Street, Harrisburg, PA 17110 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 6a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,200$4,200Feb 6, 2012Closed
Citation 1, item 6b
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Feb 6, 2012Closed
Citation 1, item 7a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$3,000Feb 6, 2012Closed
Citation 1, item 7b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Feb 6, 2012Closed
Citation 1, item 8a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$0$4,200Feb 6, 2012Closed
Citation 1, item 8b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 6, 2012Closed
Citation 1, item 8c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,200$0Feb 6, 2012Closed

Inspection 116213604 OPENED DEC 27, 2004Closed

Accident · Complete · Safety · 6 employees at the site · Closed Jul 17, 2006

200 Muench Street, Harrisburg, PA 17103 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Dec 17, 2004 (fatal): Employee is killed in fall from scaffold

At approximately 1:30 p.m. on December 17, 2004, Employee #1, of Kemar, Inc., wa s removing old roofing shingles in Harrisburg, Pennsylvania, when he fell 21 fee t from a scaffold plank. He died.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,100$750Feb 18, 2005Final
Citation 1, item 2
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$2,100$750Feb 18, 2005Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,100$750Feb 18, 2005Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,100$750Feb 18, 2005Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.62 · Lead in construction

Other residential remodelers employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.