OSHA SearchOSHA records by employer

Kennedy's Heating & Air, Inc.: OSHA inspections and violations

Statesboro, Georgia · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
5citation items
$4,880current penalties
Sep 18, 2015last inspection

OSHA has inspected Kennedy's Heating & Air, Inc. 2 times in Georgia since 2014.

The latest one began on Sep 18, 2015 after a fatality or catastrophe, in Statesboro.

Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $6,800 and now stand at $4,880, 28% lower after settlements or reviews.

Stairways in construction comes up most often in these citations: 3 items under 1926.1052.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Kennedy's Heating & Air, Inc. averages $2,000 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Kennedy's Heating & Air, Inc.: OSHA citation items per year, 2014 to 2015
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

150employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Kennedy's Heating & Air, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340936848 OPENED SEP 18, 2015Closed

Fatality or catastrophe · Complete · Safety · 5 employees at the site · Closed Jan 29, 2016

21249 Highway 80 West, Statesboro, GA 30458 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 1, 2015 (fatal): Employee is electrocuted while working in the crawl space of

At 11:30 a.m. on July 1, 2015, an employee was performing general annual maintenance on a residential heating and air condition system that included a dehumidifier in the crawl space of the residence. The dehumidifier was a Healthy Air DVA 150 that was located in the crawl space. The weather conditions for the day of the event are unknown. The owner of the residence found the employee at approximately 6:00 PM. The employee was working alone. It is suspected the left forearm of the employee came into contact with the housing of the dehumidifier, resulting in a fatal electric shock.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.39(a)(1) · Reporting deaths and severe injuries
Other-than-serious$2,000$2,000Dec 30, 2015Final

Inspection 339569329 OPENED JAN 31, 2014Closed

Referral · Partial · Safety · 8 employees at the site · Closed May 22, 2014

52 Aspen Heights, Statesboro, GA 30458 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$1,600$960Apr 15, 2014Final
Citation 1, item 2a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$1,600$960Apr 15, 2014Final
Citation 1, item 2b
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0Apr 15, 2014Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,600$960Apr 15, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(1)

(a) Basic requirement. (1) Within eight (8) hours after the death of any employee as a result of a work-related incident, you must report the fatality to the Occupational Safety and Health Administration (OSHA), U.S. Department of Labor.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1053 · Ladders in construction

Other plumbing, heating, and air-conditioning contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.