OSHA SearchOSHA records by employer

Kerns Masonry Inc.: OSHA inspections and violations

Washington, District of Columbia · Masonry Contractors · NAICS 238140

2inspections
7citation items
$16,920current penalties
Jul 9, 2018last inspection

Since 2015, OSHA inspectors have visited Kerns Masonry Inc. in District of Columbia 2 times.

The most recent inspection opened on Jul 9, 2018 as a planned inspection, in Washington.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $17,520; today they stand at $16,920, 3% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Kerns Masonry Inc. averages $8,460 across 2 cited inspections.

Kerns Masonry Inc.: OSHA citation items per year, 2015 to 2018
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

14employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch Kerns Masonry Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343290847 OPENED JUL 9, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 6, 2023

4664 Broad Branch Nw, Washington, DC 20011 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$3,880$3,880Nov 14, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,880$3,880Nov 14, 2018Final
Citation 1, item 3
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$3,880$3,880Nov 14, 2018Final
Citation 1, item 4
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$3,880$3,880Nov 14, 2018Final

Inspection 340436039 OPENED FEB 27, 2015Closed

Planned · Partial · Safety · 2 employees at the site · Closed Aug 17, 2015

1351 Wisconsin Ave. Nw, Washington, DC 20007 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,000$1,400Apr 28, 2015Final
Citation 1, item 1b
29 CFR 1926.451(e)(5)(i) · Scaffolds, general requirements
Serious$0$0Apr 28, 2015Final
Citation 1, item 1c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Apr 28, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

Other masonry contractors employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.