OSHA SearchOSHA records by employer

KGFM, LLC: OSHA inspections and violations

Thibodaux, Louisiana · Masonry Contractors · NAICS 238140

1inspections
3citation items
$4,214current penalties
Jun 10, 2021last inspection

OSHA has inspected KGFM, LLC once in Louisiana.

The inspection began on Jun 10, 2021 as a planned inspection, in Thibodaux.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $7,023 and now stand at $4,214, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and KGFM, LLC averages $4,214 (1 cited inspection).

KGFM, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

23employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch KGFM, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345357016 OPENED JUN 10, 2021Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 15, 2021

175 Magazine Loop, Thibodaux, LA 70301 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,341$1,405Jul 14, 2021Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,341$1,405Jul 14, 2021Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,341$1,405Jul 14, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other masonry contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.