OSHA SearchOSHA records by employer

Kinder Morgan Production Company, LLC: OSHA inspections and violations

Iraan, Texas · Oil and Gas Extraction · NAICS 211111

3inspections
4citation items
$16,200current penalties
Apr 4, 2017last inspection

Kinder Morgan Production Company, LLC has 3 OSHA inspections on record in Texas, the first in 2016.

OSHA's last visit started on Apr 4, 2017 to follow up on an earlier case, in Iraan.

Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

OSHA proposed $25,395 in penalties. After settlements and reviews the total is $16,200, down 36%.

Most often, OSHA cited 1910.333, working near live electrical parts (3 items).

For context, across all mining and oil and gas employers the median penalty per cited inspection since 2015 is $2,883. Kinder Morgan Production Company, LLC averages $16,200 over 1 cited inspection in that time.

It reported 2 severe injuries to OSHA since 2015.

Kinder Morgan Production Company, LLC: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

405employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Kinder Morgan Production Company, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342227949 OPENED APR 4, 2017Closed

Follow-up · Partial · Safety · 100 employees at the site · Closed Jul 10, 2017

1800 Hwy 190 West, Iraan, TX 79744 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342028297 OPENED JAN 12, 2017Closed

Referral · Partial · Safety · 92 employees at the site · Closed May 3, 2017

Yates Field Unit Well # 403 Rrc # 004a03, Iraan, TX 79744 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps

Incident on Jan 9, 2017: Employee is overcome by well oil and gas extraction gases

At 9:45 a.m. on January 9, 2017, an employee was working for a firm engaged in crude petroleum and natural gas extraction. He was testing the level in a well through the use of an "EKO gun." The employee connected the EKO gun to shoot the level ("check the well level"). When he cranked a two-section ball valve, a few threads slipped out. The valve split open and sprayed gas onto the employee. The well gases included hydrogen sulfide, methane, and so forth. The employee was overcome by the gases, but he was not suffocated. He was hospitalized. hospitalized.

No citations from this inspection.

Inspection 341776136 OPENED SEP 14, 2016Closed

Referral · Partial · Safety · 100 employees at the site · Closed Feb 24, 2017

1800 Hwy 190 West, Iraan, TX 79744 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$8,465$6,000Jan 20, 2017Final
Citation 1, item 1b
29 CFR 1910.333(b)(2)(iv) · Working near live electrical parts
Serious$0$0Jan 20, 2017Final
Citation 1, item 2
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Other-than-serious$8,465$4,200Jan 20, 2017Final
Citation 1, item 3
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$8,465$6,000Jan 20, 2017Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jan 9, 2017, Iraan: Hospitalization · poisoning, toxic, noxious, or allergenic effect, unspecified · body systems

An employee was preparing to shoot a fluid level on a well. He screwed an echo gun onto the well casing and opened the casing valve. When the pressure hit the gun, the outside of the casing valve threads failed and the pressure popped, releasing H2S (hydrogen sulfide) gas into the employee's face.

Sep 13, 2016, Iraan: Hospitalization · electrical burns, unspecified · arm(s), unspecified

While troubleshooting electrical problems in the main control panels, an employee made contact with a phase from the bus and was shocked, suffering arm burns.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1910.333(b)(2)(i)

(i) Procedures. The employer shall maintain a written copy of the procedures outlined in paragraph (b)(2) and shall make it available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives.

29 CFR 1910.333(b)(2)(iv)

(iv) Verification of deenergized condition. The requirements of this paragraph shall be met before any circuits or equipment can be considered and worked as deenergized.

29 CFR 1910.335 · Safeguards for personnel protection

Other oil and gas extraction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.