Inspection 342554896 OPENED AUG 15, 2017Closed
208 West 11th Street, New York, NY 10014 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2016, OSHA inspectors have visited King Construction Group in New York 2 times.
The most recent inspection opened on Aug 15, 2017 to follow up on an earlier case, in New York.
In all, OSHA issued 5 citation items: 5 serious.
The penalties, $18,108 in total, stand where OSHA first set them.
The rule cited most here is 1926.403 (electrical equipment on job sites), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. King Construction Group averages $18,108 across 1 cited inspection.
New York · latest 90 days of OSHA records
362employers cited
13 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch King Construction Group and get notified the morning OSHA posts a new citation for it.
Watch this company208 West 11th Street, New York, NY 10014 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
208 W 11th St., New York, NY 10014 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(f) · Electrical equipment on job sites |
Serious | $2,897 | $2,897 | Mar 10, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites |
Serious | $5,070 | $5,070 | Mar 10, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $3,622 | $3,622 | Mar 10, 2017 | Final |
| Citation 1, item 4 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $2,897 | $2,897 | Mar 10, 2017 | Final |
| Citation 1, item 5 29 CFR 1926.1052(c)(1) · Stairways in construction |
Serious | $3,622 | $3,622 | Mar 10, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(c)(1)
(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:
29 CFR 1926.403(f)
(f) Arcing parts. Parts of electric equipment which in ordinary operation produce arcs, sparks, flames, or molten metal shall be enclosed or separated and isolated from all combustible material.
29 CFR 1926.403(i)(2)(i)
(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.