OSHA SearchOSHA records by employer

Kings Remodeling LLC: OSHA inspections and violations

Fairfield, Connecticut · Residential Remodelers · NAICS 236118

1inspections
2citation items
$3,137current penalties
Mar 8, 2017last inspection

OSHA has inspected Kings Remodeling LLC once in Connecticut.

The inspection began on Mar 8, 2017 as a planned inspection, in Fairfield.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $4,482 and now stand at $3,137, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Kings Remodeling LLC averages $3,137 (1 cited inspection).

Kings Remodeling LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

83employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Kings Remodeling LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342162724 OPENED MAR 8, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Dec 9, 2019

496 Penfield Road, Fairfield, CT 06824 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,173$1,521Apr 5, 2017Final
Citation 1, item 2
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$2,309$1,616Apr 5, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(d)(15)

(15) Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows: