OSHA SearchOSHA records by employer

Kingspan Incorporated: OSHA inspections and violations

Mount Vernon, New York · Masonry Contractors · NAICS 238140

1inspections
3citation items
$8,550current penalties
Jan 11, 2016last inspection

OSHA inspectors have visited Kingspan Incorporated in New York one time.

It opened on Jan 11, 2016 on a referral, in Mount Vernon.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $17,100; today they stand at $8,550, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Kingspan Incorporated averages $8,550 across 1 cited inspection.

Kingspan Incorporated: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Kingspan Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341249910 OPENED JAN 11, 2016Closed

Referral · Partial · Safety · 150 employees at the site · Closed Feb 14, 2018

203 Gramatan Ave, Mount Vernon, NY 10550 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$6,300$3,650Jul 7, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$6,300$3,650Jul 7, 2016Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$4,500$1,250Jul 7, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(g)(4)(xv)

(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.454(a)

(a) The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable: