OSHA SearchOSHA records by employer

KM Kerry Masonry, Inc.: OSHA inspections and violations

Chicago, Illinois · Masonry Contractors · NAICS 238140

1inspections
7citation items
$15,000current penalties
Jun 2, 2015last inspection

OSHA has inspected KM Kerry Masonry, Inc. once in Illinois.

The inspection began on Jun 2, 2015 as a planned inspection, in Chicago.

That inspection ended with 7 citation items: 6 serious and 1 repeat.

Penalties were first proposed at $22,880 and now stand at $15,000, 34% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and KM Kerry Masonry, Inc. averages $15,000 (1 cited inspection).

KM Kerry Masonry, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

428employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch KM Kerry Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340674944 OPENED JUN 2, 2015Closed

Planned · Partial · Health · 12 employees at the site · Closed Jan 13, 2017

7421-23 South King Drive, Chicago, IL 60615 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,320$1,000Aug 28, 2015Final
Citation 1, item 1b
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$0$0Aug 28, 2015Final
Citation 1, item 2a
29 CFR 1926.451(d)(16) · Scaffolds, general requirements
Serious$3,080$2,000Aug 28, 2015Final
Citation 1, item 2b
29 CFR 1926.451(d)(17) · Scaffolds, general requirements
Serious$0$0Aug 28, 2015Final
Citation 1, item 3a
29 CFR 1926.451(g)(1)(ii) · Scaffolds, general requirements
Serious$3,080$2,000Aug 28, 2015Final
Citation 1, item 3b
29 CFR 1926.451(g)(4) · Scaffolds, general requirements
Serious$0$0Aug 28, 2015Final
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$15,400$10,000Aug 28, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(16)

(16) In addition to the normal operating brake, suspension scaffold power-operated hoists and manually operated hoists shall have a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed.

29 CFR 1926.451(d)(17)

(17) Manually operated hoists shall require a positive crank force to descend.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.