OSHA SearchOSHA records by employer

Kmi, Inc.: OSHA inspections and violations

Brooklyn, New York · Masonry Contractors · NAICS 238140

1inspections
3citation items
$49,650current penalties
Oct 28, 2025last inspection

OSHA has inspected Kmi, Inc. once in New York.

The inspection began on Oct 28, 2025 on a referral, in Brooklyn; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $49,650 and still stand at $49,650.

Requirements for cast-in-place concrete comes up most often in these citations: 3 items under 1926.703.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Kmi, Inc. averages $49,650 (1 cited inspection).

Kmi, Inc.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Kmi, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348572736 OPENED OCT 28, 2025Open

Referral · Partial · Safety · 108 employees at the site · Open

6208 8th Ave., Brooklyn, NY 11220 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.703(a)(1) · Requirements for cast-in-place concrete
Serious$16,550$16,550Apr 27, 2026Contested
Citation 1, item 2
29 CFR 1926.703(b)(8)(i) · Requirements for cast-in-place concrete
Serious$16,550$16,550Apr 27, 2026Contested
Citation 1, item 3
29 CFR 1926.703(b)(8)(iv) · Requirements for cast-in-place concrete
Serious$16,550$16,550Apr 27, 2026Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.703 · Requirements for cast-in-place concrete

29 CFR 1926.703(a)(1)

(a) General requirements for formwork. (1) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be capable of supporting without failure all vertical and lateral loads that may reasonably be anticipated to be applied to the formwork. Formwork which is designed, fabricated, erected, supported, braced and maintained in conformance with the appendix to this section will be deemed to meet the requirements of this paragraph.

29 CFR 1926.703(b)(8)(i)

(i) The design of the shoring shall be prepared by a qualified designer and the erected shoring shall be inspected by an engineer qualified in structural design.

29 CFR 1926.703(b)(8)(iv)

(iv) The single post shores shall be adequately braced in two mutually perpendicular directions at the splice level. Each tier shall also be diagonally braced in the same two directions.

Other masonry contractors employers in New York