OSHA SearchOSHA records by employer

Knight Restoration Services: OSHA inspections and violations

Dallas, Texas · Remediation Services · NAICS 562910

1inspections
1citation items
$3,104current penalties
Oct 18, 2018last inspection

OSHA inspectors have visited Knight Restoration Services in Texas one time.

It opened on Oct 18, 2018 after a complaint, in Dallas.

In all, OSHA issued 1 citation item: 1 serious.

No penalty came with these citations.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,208 penalty. Knight Restoration Services averages $3,104 across 1 cited inspection.

Knight Restoration Services: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Knight Restoration Services and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343548137 OPENED OCT 18, 2018Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Dec 7, 2018

2050 N. Stemmons Freeway, Dallas, TX 75207 · Remediation Services · OSHA's record · Phone and website on Google Maps

Incident on Nov 10, 2018: Employee sustains electric shocks to hands while operating f

At 9:30 a.m. on November 10, 2018, an employee was operating a Galaxy floor scrubber machine while removing some old flooring debris and sustained electrical shocks to his hands. Hospitalization was not required.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites
Serious$0$3,104Nov 9, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(iii)(c)

(C) Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.

Other remediation services employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.