Knox County - Concord Park: OSHA inspections and violations

Knoxville, Tennessee · Administration of Conservation Programs · NAICS 924120

1inspections
3citation items
$0current penalties
Oct 6, 2020last inspection

OSHA inspectors have visited Knox County - Concord Park in Tennessee one time.

It opened on Oct 6, 2020 as a planned inspection, in Knoxville.

In all, OSHA issued 3 citation items: 3 serious.

No penalty came with these citations.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Knox County - Concord Park averages $0 across 1 cited inspection.

Knox County - Concord Park: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

339employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Knox County - Concord Park and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344963335 OPENED OCT 6, 2020Closed

Planned · Complete · Safety · Local government · 25 employees at the site · Closed Nov 2, 2020

10901 South Northshore Drive, Knoxville, TN 37922 · Administration of Conservation Programs · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Serious$0$0Oct 19, 2020Final
Citation 1, item 2
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Oct 19, 2020Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Oct 19, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

Other administration of conservation programs employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.