OSHA SearchOSHA records by employer

Knox Custom Fabrication, Inc.: OSHA inspections and violations

North Salt Lake, Utah · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

2inspections
2citation items
$1,125current penalties
Jan 31, 2020last inspection

Knox Custom Fabrication, Inc. has 2 OSHA inspections on record in Utah, the first in 2016.

OSHA's last visit started on Jan 31, 2020 after a complaint, in North Salt Lake.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $2,250 in penalties. After settlements and reviews the total is $1,125, down 50%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Knox Custom Fabrication, Inc. averages $1,125 over 1 cited inspection in that time.

Knox Custom Fabrication, Inc.: OSHA citation items per year, 2016 to 2020
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

73employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Knox Custom Fabrication, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344597331 OPENED JAN 31, 2020Closed

Complaint · Partial · Health · 5 employees at the site · Closed Jan 31, 2020

685 W 600 N, North Salt Lake, UT 84054 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341374270 OPENED APR 5, 2016Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 12, 2016

685 W 600 N, North Salt Lake, UT 84054 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,500$750May 9, 2016Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$375May 9, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.