OSHA SearchOSHA records by employer

Koch Tenn Inc: OSHA inspections and violations

Whitesburg, Tennessee · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

3inspections
27citation items
$17,076current penalties
May 26, 2016last inspection

Since 2015, OSHA inspectors have visited Koch Tenn Inc in Tennessee 3 times.

The most recent inspection opened on May 26, 2016 to monitor an earlier case, in Whitesburg.

In all, OSHA issued 27 citation items: 22 serious and 5 other-than-serious.

The proposed penalties came to $21,000; today they stand at $17,076, 19% less.

The rule cited most here is 1910.1030 (bloodborne pathogens), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Koch Tenn Inc averages $8,538 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Koch Tenn Inc also files yearly injury logs with OSHA, summarized below.

Koch Tenn Inc: OSHA citation items per year, 2015 to 2016
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Koch Tenn Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341505741 OPENED MAY 26, 2016Closed

Monitoring · Partial · Health · 77 employees at the site · Closed Sep 9, 2016

1701 Needmore Rd., Whitesburg, TN 37891 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341021533 OPENED OCT 27, 2015Closed

Referral · Partial · Health · 81 employees at the site · Closed Jun 2, 2016

1701 Needmore Rd., Whitesburg, TN 37891 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,750$1,125Mar 23, 2016Final
Citation 1, item 1b Serious$0$0Mar 23, 2016Final
Citation 1, item 1c Serious$0$0Mar 23, 2016Final
Citation 1, item 1d Serious$0$0Mar 23, 2016Final
Citation 1, item 1e Serious$0$0Mar 23, 2016Final
Citation 1, item 2b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$1,365Mar 23, 2016Final
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,500$1,170Mar 23, 2016Final
Citation 1, item 4a
29 CFR 1910.1030(c)(1)(iv) · Bloodborne pathogens
Serious$1,250$975Mar 23, 2016Final
Citation 1, item 4b
29 CFR 1910.1030(c)(2)(i)(c) · Bloodborne pathogens
Serious$0$0Mar 23, 2016Final
Citation 1, item 4c
29 CFR 1910.1030(g)(2)(ii)(b) · Bloodborne pathogens
Serious$0$0Mar 23, 2016Final
Citation 1, item 4d
29 CFR 1910.1030(g)(2)(vii)(f) · Bloodborne pathogens
Serious$0$0Mar 23, 2016Final
Citation 1, item 4e
29 CFR 1910.1030(h)(2)(i)(b) · Bloodborne pathogens
Serious$0$0Mar 23, 2016Final
Citation 1, item 4f
29 CFR 1910.1030(h)(2)(i)(c) · Bloodborne pathogens
Serious$0$0Mar 23, 2016Final
Citation 1, item 5a
29 CFR 1910.1200(e)(2) · Hazard communication
Serious$1,750$1,365Mar 23, 2016Final
Citation 1, item 5b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 23, 2016Final
Citation 1, item 5c
29 CFR RULE 800-01-09-.06(2)
Serious$0$0Mar 23, 2016Final
Citation 1, item 5d
29 CFR RULE 800-01-09-.07(4)
Serious$0$0Mar 23, 2016Final

Inspection 340975598 OPENED OCT 8, 2015Closed

Fatality or catastrophe · Complete · Safety · 75 employees at the site · Closed Mar 3, 2016

1701 Needmore Rd., Whitesburg, TN 37891 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Oct 6, 2015 (fatal): Employee is electrocuted while cleaning table saw

At 3:00 p.m. on October 6, 2015, Employee #1 contacted an energized lifting table while cleaning wood dust and debris from a Lauderdale-Hamilton brand gang rip saw and the surrounding area. The employee cleaned the machine every 2 to 3 weeks since February 2015. The machines were cleaned using an air hose and broom. Employee#1 was found lying face down and unresponsive between the lifting table and the gang rip saw. Employee#2 was shocked trying to move the body to administer aid. The gang rip saw was de-energized and Employee #1 was moved to an area where first-responders began CPR. Local rescue personnel were called and took over first aid upon arrival and removed employee #1. In the main electrical panel for the rip saw, 2 of 3 fuses tripped. The third fuse did not trip because the surge of electricity caused the contact inside the panel to weld itself open. The lifting table was equipped with a flexible power cord which was connected to a receptacle located on a power box which was fixed to the frame of the gang rip saw. The grounding wire located inside the receptacle was covered in insulation where it was attached to the grounding lug; thus rendering the ground wire ineffective. Further review of the power cord revealed the cord had seven areas of damage to the sheath and insulation, including two complete breaks which were spliced together and then covered by electrical tape. Damage to the flexible cord allowed the copper wiring contained in the cord to make contact with the lifting table, resulting in the table becoming energized. In combination with the improperly grounded receptacle, this allowed electricity to travel from the lifting table through Employee #1 and into the nearby grounded gang rip saw. Employee #1 was electrocuted. electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$4,000$3,000Jan 27, 2016Final
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,250$938Jan 27, 2016Final
Citation 1, item 3
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Serious$4,000$3,000Jan 27, 2016Final
Citation 1, item 4
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$4,000$3,000Jan 27, 2016Final
Citation 1, item 5
29 CFR 1910.333(b)(2) · Working near live electrical parts
Serious$1,250$938Jan 27, 2016Final
Citation 2, item 1
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$125$100Jan 27, 2016Final
Citation 2, item 2
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Other-than-serious$0$0Jan 27, 2016Final
Citation 2, item 3
29 CFR 1910.106(h)(8)(iii) · Flammable liquids
Other-than-serious$125$100Jan 27, 2016Final
Citation 2, item 4
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$0$0Jan 27, 2016Final
Citation 2, item 5
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Jan 27, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Whitesburg site logged 3 recordable injuries or illnesses among about 139 workers: 2.3 per 100 full-time workers, against a median of 4.6 for its industry. Those cases cost 17 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Koch Tenn
Whitesburg · 2025
139 312.34.6

Included with any plan: 2 more yearly logs from these sites, back to 2023, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(iv)

(iv) The Exposure Control Plan shall be reviewed and updated at least annually and whenever necessary to reflect new or modified tasks and procedures which affect occupational exposure and to reflect new or revised employee positions with occupational exposure. The review and update of such plans shall also:

29 CFR 1910.1030(c)(2)(i)(c)

(C) A list of all tasks and procedures or groups of closely related task and procedures in which occupational exposure occurs and that are performed by employees in job classifications listed in accordance with the provisions of paragraph (c)(2)(i)(B) of this standard.

29 CFR 1910.1030(g)(2)(ii)(b)

(B) At least annually thereafter.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other wood kitchen cabinet and countertop manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.