OSHA SearchOSHA records by employer

Koller Industries: OSHA inspections and violations

Niagara, Wisconsin · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

4inspections
29citation items
$37,450current penalties
Feb 26, 2019last inspection

Since 2015, OSHA inspectors have visited Koller Industries in Wisconsin 4 times.

The most recent inspection opened on Feb 26, 2019 after a complaint, in Niagara.

In all, OSHA issued 29 citation items: 15 serious, 1 willful and 13 repeat.

The proposed penalties came to $236,791; today they stand at $37,450, 84% less.

The rule cited most here is 1910.215 (grinders and abrasive wheels), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Koller Industries averages $9,362 across 4 cited inspections.

Koller Industries: OSHA citation items per year, 2015 to 2019
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

231employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Koller Industries and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343810057 OPENED FEB 26, 2019Closed

Complaint · Partial · Health · 25 employees at the site · Closed Aug 13, 2021

1191 County Road B., Niagara, WI 54151 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$4,168$2,000Aug 22, 2019Final
Citation 1, item 1b Serious$0$0Aug 22, 2019Final

Inspection 343810461 OPENED FEB 26, 2019Closed

Complaint · Partial · Safety · 25 employees at the site · Closed Jul 7, 2023

1191 County Road B., Niagara, WI 54151 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$5,834$1,250Aug 22, 2019Final
Citation 1, item 1b
29 CFR 1910.147(d) · Lockout/tagout
Serious$0$1,250Aug 22, 2019Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$5,834$1,250Aug 22, 2019Final
Citation 1, item 3
29 CFR 1910.215(d)(1) · Grinders and abrasive wheels
Serious$5,834$1,250Aug 22, 2019Final
Citation 1, item 4
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$4,168$1,250Aug 22, 2019Final
Citation 1, item 5
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$4,168$1,250Aug 22, 2019Final
Citation 1, item 6a
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$4,168$1,250Aug 22, 2019Final
Citation 1, item 6b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$1,250Aug 22, 2019Final
Citation 1, item 7
29 CFR 1910.305(i)(3) · Electrical wiring methods
Serious$4,168$1,250Aug 22, 2019Final
Citation 2, item 1
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Willful$72,929$1,250Aug 22, 2019Final
Citation 3, item 1
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Repeat$11,669$1,250Aug 22, 2019Final
Citation 3, item 2a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Repeat$29,172$1,250Aug 22, 2019Final
Citation 3, item 2b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Repeat$0$1,250Aug 22, 2019Final
Citation 3, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Repeat$4,169$1,250Aug 22, 2019Final
Citation 3, item 4
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Repeat$20,838$1,250Aug 22, 2019Final
Citation 3, item 5
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Repeat$29,172$1,250Aug 22, 2019Final

Inspection 341062909 OPENED NOV 18, 2015Closed

Follow-up · Partial · Health · 36 employees at the site · Closed Jan 14, 2016

1191 County Road B., Niagara, WI 54151 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Repeat$200$200Dec 10, 2015Final

Inspection 341066009 OPENED NOV 18, 2015Closed

Complaint · Partial · Safety · 36 employees at the site · Closed Nov 21, 2019

1191 County Road B., Niagara, WI 54151 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(3) · Exit routes
Serious$2,100$1,050Mar 25, 2016Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,500$1,750Mar 25, 2016Final
Citation 1, item 2b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0Mar 25, 2016Final
Citation 1, item 3
29 CFR 1910.303(c)(3)(i) · Electrical equipment, general requirements
Serious$3,500$1,750Mar 25, 2016Final
Citation 2, item 1a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Repeat$7,000$3,500Mar 25, 2016Final
Citation 2, item 1b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Repeat$0$0Mar 25, 2016Final
Citation 2, item 1c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Repeat$0$0Mar 25, 2016Final
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Repeat$200$200Mar 25, 2016Final
Citation 2, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Repeat$7,000$3,500Mar 25, 2016Final
Citation 2, item 4
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Repeat$7,000$3,500Mar 25, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(5)(i)

(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other electroplating, plating, polishing, anodizing, and coloring employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.