OSHA SearchOSHA records by employer

Kraemer Lumber Co Inc: OSHA inspections and violations

Melrose, Minnesota · Home Centers · NAICS 444110

1inspections
7citation items
$1,710current penalties
Feb 10, 2026last inspection

Kraemer Lumber Co Inc has one OSHA inspection on record in Minnesota.

OSHA opened it on Feb 10, 2026 as a planned inspection, in Melrose.

From that inspection OSHA issued 7 citation items: 4 serious and 3 other-than-serious.

OSHA proposed $2,850 in penalties. After settlements and reviews the total is $1,710, down 40%.

Most often, OSHA cited 1910.213, woodworking machinery (3 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Kraemer Lumber Co Inc averages $1,710 over 1 cited inspection in that time.

Kraemer Lumber Co Inc: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Kraemer Lumber Co Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348737081 OPENED FEB 10, 2026Closed

Planned · Complete · Safety · 14 employees at the site · Closed Mar 10, 2026

826 Cty Rd 13, Melrose, MN 56352 · Home Centers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$450$270Feb 19, 2026Final
Citation 1, item 2
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$750$450Feb 19, 2026Final
Citation 1, item 3
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$450$270Feb 19, 2026Final
Citation 1, item 4
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$750$450Feb 19, 2026Final
Citation 2, item 1
29 CFR 1910.23(c)(11) · Ladders in general industry
Other-than-serious$150$90Feb 19, 2026Final
Citation 2, item 2
29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry
Other-than-serious$150$90Feb 19, 2026Final
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$150$90Feb 19, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.

29 CFR 1910.213(c)(3)

(3) Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut.

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.305 · Electrical wiring methods

Other home centers employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.