OSHA SearchOSHA records by employer

Krain Building Services, LLC: OSHA inspections and violations

Fairfax, Virginia · Clay Building Material and Refractories Manufacturing · NAICS 327122

2inspections
19citation items
$1,800current penalties
Nov 9, 2017last inspection

Since 2009, OSHA inspectors have visited Krain Building Services, LLC in Virginia 2 times.

The most recent inspection opened on Nov 9, 2017 after a complaint, in Alexandria.

In all, OSHA issued 19 citation items: 16 serious and 3 other-than-serious.

The penalties, $1,800 in total, stand where OSHA first set them.

The rule cited most here is 1910.95 (noise), 8 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Krain Building Services, LLC averages $1,800 across 1 cited inspection.

Krain Building Services, LLC: OSHA citation items per year, 2009 to 2017
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Krain Building Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342768140 OPENED NOV 9, 2017Closed

Complaint · Partial · Health · 25 employees at the site · Closed Jun 11, 2018

6698 Fleet Drive, Alexandria, VA 22310 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$600$600Apr 17, 2018Final
Citation 1, item 1b Serious$0$0Apr 17, 2018Final
Citation 1, item 1c Serious$0$0Apr 17, 2018Final
Citation 1, item 1d Serious$0$0Apr 17, 2018Final
Citation 1, item 1e Serious$0$0Apr 17, 2018Final
Citation 1, item 1f Serious$0$0Apr 17, 2018Final
Citation 1, item 1g Serious$0$0Apr 17, 2018Final
Citation 1, item 1h Serious$0$0Apr 17, 2018Final
Citation 1, item 2a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$600$600Apr 17, 2018Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Apr 17, 2018Final
Citation 1, item 2c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Apr 17, 2018Final
Citation 1, item 2d
29 CFR 1910.134(k)(6) · Respiratory protection
Serious$0$0Apr 17, 2018Final
Citation 1, item 3a
29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements
Serious$600$600Apr 17, 2018Final
Citation 1, item 3b
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Serious$0$0Apr 17, 2018Final
Citation 1, item 3c
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Apr 17, 2018Final
Citation 1, item 3d
29 CFR 1910.305(j)(2)(vii) · Electrical wiring methods
Serious$0$0Apr 17, 2018Final
Citation 2, item 1
29 CFR 1910.38(b) · Emergency action plans
Other-than-serious$0$0Apr 17, 2018Final
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Apr 17, 2018Final
Citation 2, item 3
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Apr 17, 2018Final

Inspection 314002536 OPENED DEC 3, 2009Closed

Planned · No inspection · Safety · 1 employee at the site · Closed Dec 3, 2009

2929 Eskridge Road, Suite B, Fairfax, VA 22031 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(h)(2)(i)

(i) All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.95 · Noise

Other clay building material and refractories manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.