OSHA SearchOSHA records by employer

Kranjec Midwest: OSHA inspections and violations

Fredericktown, Missouri · Other Animal Food Manufacturing · NAICS 311119

1inspections
8citation items
$3,474current penalties
Aug 22, 2016last inspection

OSHA inspectors have visited Kranjec Midwest in Missouri one time.

It opened on Aug 22, 2016 after a complaint, in Fredericktown.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $6,948; today they stand at $3,474, 50% less.

The rule cited most here is 1910.147 (lockout/tagout), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,872 penalty. Kranjec Midwest averages $3,474 across 1 cited inspection.

Kranjec Midwest: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Kranjec Midwest again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341717973 OPENED AUG 22, 2016Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Apr 25, 2017

320 North Mine La Motte, Fredericktown, MO 63645 · Other Animal Food Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(c)(2) · Guarding floor and wall openings and holes
Serious$2,672$1,336Sep 28, 2016Final
Citation 1, item 1b
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Serious$0$0Sep 28, 2016Final
Citation 1, item 2
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$1,604$802Sep 28, 2016Final
Citation 1, item 3a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$2,672$1,336Sep 28, 2016Final
Citation 1, item 3b
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$0$0Sep 28, 2016Final
Citation 1, item 3c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Sep 28, 2016Final
Citation 1, item 3d
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Sep 28, 2016Final
Citation 1, item 3e
29 CFR 1910.303(f)(1) · Electrical equipment, general requirements
Serious$0$0Sep 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(4)

(4) If the employer decides that its employees will enter permit spaces, the employer shall develop and implement a written permit space program that complies with this section. The written program shall be available for inspection by employees and their authorized representatives.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(5)(i)

(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

Other other animal food manufacturing employers in Missouri

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.