OSHA SearchOSHA records by employer

Kruger Roofing LLC: OSHA inspections and violations

Grand Junction, Colorado · Roofing Contractors · NAICS 238160

1inspections
4citation items
$6,000current penalties
Sep 4, 2015last inspection

OSHA inspectors have visited Kruger Roofing LLC in Colorado one time.

It opened on Sep 4, 2015 after a complaint, in Grand Junction.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $6,000 in total, stand where OSHA first set them.

The rule cited most here is 1926.502 (fall protection systems), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Kruger Roofing LLC averages $6,000 across 1 cited inspection.

Kruger Roofing LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

130employers cited

20 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Kruger Roofing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340914415 OPENED SEP 4, 2015Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Oct 21, 2015

2915 Orchard Ave, Grand Junction, CO 81504 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,400$2,400Sep 25, 2015Final
Citation 1, item 2a
29 CFR 1926.502(f)(1) · Fall protection systems
Serious$2,400$2,400Sep 25, 2015Final
Citation 1, item 2b
29 CFR 1926.502(h)(1)(v) · Fall protection systems
Serious$0$0Sep 25, 2015Final
Citation 1, item 3
29 CFR 1926.252(a) · Disposal of waste materials
Serious$1,200$1,200Sep 25, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.252 · Disposal of waste materials

29 CFR 1926.252(a)

(a) Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, shall be used. For the purpose of this paragraph, an enclosed chute is a slide, closed in on all sides, through which material is moved from a high place to a lower one.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(f)(1)

(1) The warning line shall be erected around all sides of the roof work area.