OSHA SearchOSHA records by employer

Kygo Masonry, LLC: OSHA inspections and violations

Lutz, Florida · Masonry Contractors · NAICS 238140

2inspections
7citation items
$5,967current penalties
Aug 18, 2026last inspection

OSHA has inspected Kygo Masonry, LLC 2 times in Florida since 2018.

The latest one began on Aug 18, 2026 after a complaint, in Crestview; the case is still open.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $11,934 and now stand at $5,967, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Kygo Masonry, LLC averages $5,967 (1 cited inspection).

Kygo Masonry, LLC: OSHA citation items per year, 2018 to 2026
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Kygo Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349120295 OPENED AUG 18, 2026Open

Complaint · Complete · Health · 5 employees at the site · Open

New Okaloosa County Tax Collectors Office In Crestview Fl 1448 Commerce Dr, Crestview, FL 32539 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 343555900 OPENED OCT 24, 2018Closed

Unprogrammed other · Partial · Safety · 8 employees at the site · Closed Jun 21, 2019

25442 Sierra Center Blvd, Lutz, FL 33559 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,978$1,989Mar 11, 2019Final
Citation 1, item 1b
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$0$0Mar 11, 2019Final
Citation 1, item 1c
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Mar 11, 2019Final
Citation 1, item 1d
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Mar 11, 2019Final
Citation 1, item 1e
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Mar 11, 2019Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,978$1,989Mar 11, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,978$1,989Mar 11, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.