OSHA SearchOSHA records by employer

L & M Marble & Granite, Inc.: OSHA inspections and violations

North Grafton, Massachusetts · Cut Stone and Stone Product Manufacturing · NAICS 327991

1inspections
15citation items
$11,916current penalties
Mar 20, 2026last inspection

OSHA has inspected L & M Marble & Granite, Inc. once in Massachusetts.

The inspection began on Mar 20, 2026 after a complaint, in North Grafton; the case is still open.

That inspection ended with 15 citation items: 14 serious and 1 other-than-serious.

Penalties were first proposed at $23,832 and now stand at $11,916, 50% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 5 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and L & M Marble & Granite, Inc. averages $11,916 (1 cited inspection).

L & M Marble & Granite, Inc.: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

264employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch L & M Marble & Granite, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348822123 OPENED MAR 20, 2026Open

Complaint · Partial · Health · 8 employees at the site · Open

218 Worcester Street Attn: Filipe Ferreira, North Grafton, MA 01536 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,972$3,972Jun 5, 2026Final
Citation 1, item 1b
29 CFR 1910.134(d)(1)(ii) · Respiratory protection
Serious$0$0Jun 5, 2026Final
Citation 1, item 1c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 5, 2026Final
Citation 1, item 1d
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Jun 5, 2026Final
Citation 1, item 1e
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Jun 5, 2026Final
Citation 1, item 2a
29 CFR 1910.1053(d)(1) · Silica dust in general industry
Serious$3,972$3,972Jun 5, 2026Final
Citation 1, item 2b
29 CFR 1910.1053(f)(2)(i) · Silica dust in general industry
Serious$3,972$0Jun 5, 2026Final
Citation 1, item 2c
29 CFR 1910.1053(i)(1)(i) · Silica dust in general industry
Serious$3,972$0Jun 5, 2026Final
Citation 1, item 3a
29 CFR 1910.1053(j)(1) · Silica dust in general industry
Serious$3,972$3,972Jun 5, 2026Final
Citation 1, item 3b
29 CFR 1910.1053(j)(3)(i) · Silica dust in general industry
Serious$0$0Jun 5, 2026Final
Citation 1, item 3c
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,972$0Jun 5, 2026Final
Citation 1, item 3d
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$0$0Jun 5, 2026Final
Citation 1, item 3e
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jun 5, 2026Final
Citation 1, item 3f
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jun 5, 2026Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jun 5, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(d)(1)

(d) Exposure assessment—(1) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section.

29 CFR 1910.1053(f)(2)(i)

(2) Written exposure control plan. (i) The employer shall establish and implement a written exposure control plan that contains at least the following elements:

29 CFR 1910.1053(i)(1)(i)

(i) Medical surveillance—(1) General. (i) The employer shall make medical surveillance available at no cost to the employee, and at a reasonable time and place, for each employee who will be occupationally exposed to respirable crystalline silica at or above the action level for 30 or more days per year.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

Other cut stone and stone product manufacturing employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.