OSHA SearchOSHA records by employer

L-Con Inc.: OSHA inspections and violations

Houston, Texas · Oil and Gas Pipeline and Related Structures Construction · NAICS 237120

2inspections
3citation items
$23,175current penalties
Aug 13, 2016last inspection

L-Con Inc. has 2 OSHA inspections on record in Texas, the first in 2012.

OSHA's last visit started on Aug 13, 2016, in Nederland.

Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $26,675 in penalties. After settlements and reviews the total is $23,175, down 13%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. L-Con Inc. averages $12,675 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

L-Con Inc.: OSHA citation items per year, 2012 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites L-Con Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341698553 OPENED AUG 13, 2016Closed

Other · Partial · Safety · 56 employees at the site · Closed Feb 26, 2018

2300 N. Twin City Highway, Nederland, TX 77627 · Pipeline Transportation of Crude Oil · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(d)(5)(ii) · Lockout/tagout
Other-than-serious$12,675$12,675Feb 7, 2017Final

Inspection 335509006 OPENED JUN 2, 2012Closed

Fatality or catastrophe · Partial · Safety · 5 employees at the site · Closed Apr 6, 2015

15631 Jacintoport Blvd., Houston, TX 77015 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Jun 2, 2012 (fatal): Employee is decapitated by exploding fragments of the plumbe

At approximately 8:15 a.m. on June 2, 2012, an employee was using an arc welder to weld a flange piece onto the end of a recently cut pipe for pipe revisions. A pipe that had contained crude oil had been cut and a Foreman's Night Cap (Plumber's Plug) had been installed approximately two feet into the open end of the pipe. The remnants of the crude oil between the cut and of the pipe and the Plumber's Plug had been wiped up with an absorbent pad. The Flange was placed over the end of the pipe and the employee began welding. The next day, the employee continued welding operations. An explosion occurred and the Plumber's Plug blew out of the open end of the pipe, striking the employee. The employee was decapitated by the exploding fragments of the Plumber's Plug. Plumber's Plug.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$7,000$3,500Oct 17, 2012Final
Citation 1, item 2
29 CFR 1926.352(j) · Fire prevention
Serious$7,000$7,000Oct 17, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(d)(5)(ii)

(ii) If there is a possibility of reaccumulation of stored energy to a hazardous level, verification of isolation shall be continued until the servicing or maintenance is completed, or until the possibility of such accumulation no longer exists.

29 CFR 1926.352 · Fire prevention

29 CFR 1926.352(j)

(j) Before heat is applied to a drum, container, or hollow structure, a vent or opening shall be provided for the release of any built-up pressure during the application of heat.