OSHA SearchOSHA records by employer

L Z Developers, Inc.: OSHA inspections and violations

Chicago, Illinois · Masonry Contractors · NAICS 238140

1inspections
4citation items
$13,053current penalties
Aug 9, 2022last inspection

L Z Developers, Inc. has one OSHA inspection on record in Illinois.

OSHA opened it on Aug 9, 2022 as a planned inspection, in Chicago.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $13,053 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. L Z Developers, Inc. averages $13,053 over 1 cited inspection in that time.

L Z Developers, Inc.: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

413employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch L Z Developers, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346136948 OPENED AUG 9, 2022Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 29, 2024

2338 W. Fullerton Ave., Chicago, IL 60647 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,486$2,486Nov 14, 2022Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,108$3,108Nov 14, 2022Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,108$3,108Nov 14, 2022Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,351$4,351Nov 14, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.