OSHA SearchOSHA records by employer

La Vintage Homes, LLC: OSHA inspections and violations

New Orleans, Louisiana · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
2citation items
$3,991current penalties
Jul 26, 2018last inspection

OSHA has inspected La Vintage Homes, LLC once in Louisiana.

The inspection began on Jul 26, 2018 as a planned inspection, in New Orleans.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $6,652 and now stand at $3,991, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and La Vintage Homes, LLC averages $3,991 (1 cited inspection).

La Vintage Homes, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch La Vintage Homes, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343333936 OPENED JUL 26, 2018Closed

Planned · Partial · Safety · 1 employee at the site · Closed Nov 7, 2018

1406 Henry Clay Ave., New Orleans, LA 70118 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$3,880$2,328Sep 20, 2018Final
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,772$1,663Sep 20, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

Other new single-family housing construction (except for-sale builders) employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.