Lampley Construction Inc: OSHA inspections and violations

Gallatin, Tennessee · Poured Concrete Foundation and Structure Contractors · NAICS 238110

3inspections
3citation items
$200current penalties
Jun 15, 2020last inspection

Since 1992, OSHA inspectors have visited Lampley Construction Inc in Tennessee 3 times.

The most recent inspection opened on Jun 15, 2020 on a referral, in Gallatin.

In all, OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

The penalties, $200 in total, stand where OSHA first set them.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lampley Construction Inc averages $0 across 1 cited inspection.

Lampley Construction Inc: OSHA citation items per year, 1992 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Lampley Construction Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344795042 OPENED JUN 15, 2020Closed

Referral · Partial · Safety · 12 employees at the site · Closed Jul 17, 2020

1724 Nashville Pike, Gallatin, TN 37066 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 12, 2020: Employee is shoved into cable guard railing and fell to conc

At 7:30 a.m. on June 12, 2020, Employee #1 was working for a concrete foundation contractor. Employee #1 was pouring concrete for 3rd floor of a commercial building. Employee #1 was shoved into cable guard railing by a coworker. The cable guardrail gave way in this section allowing the Employee #1 to fall to the concrete. Employee #1 sustained a fractured hip and fractured ribs, leading to hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(b)(9) · Fall protection systems
Other-than-serious$0$0Jul 10, 2020Final

Inspection 309223527 OPENED JUN 23, 2005Closed

Planned · Complete · Safety · 7 employees at the site · Closed Aug 2, 2005

1301 Nashville Pike, Gallatin, TN 37066 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 114511793 OPENED JAN 15, 1992Closed

Planned · Complete · Safety · 11 employees at the site · Closed Mar 31, 1992

Hwy. 100, Lyles, TN 37098 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(7)(ivc) · Ground-fault protection on job sites
Serious$200$200Jan 22, 1992Closed
Citation 2, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 22, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(7)(ivc)

(C) If the equipment is one of the types listed in paragraphs (f)(7)(iv)(C)(1) through (f)(7)(iv)(C)(5) of this section. However, even though the equipment may be one of these types, it need not be grounded if it is exempted by paragraph (f)(7)(iv)(C)(6).

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(9)

(9) Top rails and midrails shall be at least one-quarter inch (0.6 cm) nominal diameter or thickness to prevent cuts and lacerations. If wire rope is used for top rails, it shall be flagged at not more than 6-foot (1.8 m) intervals with high-visibility material.

Other poured concrete foundation and structure contractors employers in Tennessee

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.