OSHA SearchOSHA records by employer

Lance Collier: OSHA inspections and violations

Butler, Pennsylvania · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
5citation items
$7,600current penalties
Jun 25, 2018last inspection

OSHA has inspected Lance Collier once in Pennsylvania.

The inspection began on Jun 25, 2018 as a planned inspection, in Butler.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $12,749 and now stand at $7,600, 40% lower after settlements or reviews.

Excavations comes up most often in these citations: 4 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Lance Collier averages $7,600 (1 cited inspection).

Lance Collier: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Lance Collier again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343255253 OPENED JUN 25, 2018Closed

Planned · Partial · Safety · 1 employee at the site · Closed Nov 8, 2022

559 2nd Street, Butler, PA 16001 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,880$2,280Aug 24, 2018Final
Citation 1, item 1b
29 CFR 1926.651(k)(2) · Excavations
Serious$0$0Aug 24, 2018Final
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$2,217$1,330Aug 24, 2018Final
Citation 1, item 3
29 CFR 1926.651(i)(3) · Excavations
Serious$3,326$1,995Aug 24, 2018Final
Citation 1, item 4
29 CFR 1926.651(j)(2) · Excavations
Serious$3,326$1,995Aug 24, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(i)(3)

(3) Sidewalks, pavements, and appurtenant structure shall not be undermined unless a support system or another method of protection is provided to protect employees from the possible collapse of such structures.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

Other plumbing, heating, and air-conditioning contractors employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.