OSHA SearchOSHA records by employer

Lance Decker: OSHA inspections and violations

Syracuse, New York · Roofing Contractors · NAICS 238160

1inspections
8citation items
$800current penalties
Feb 5, 2019last inspection

OSHA inspectors have visited Lance Decker in New York one time.

It opened on Feb 5, 2019 on a referral, in Syracuse.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $14,208; today they stand at $800, 94% less.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Lance Decker averages $800 across 1 cited inspection.

Lance Decker: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Lance Decker again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343763686 OPENED FEB 5, 2019Closed

Referral · Complete · Safety · 8 employees at the site · Closed Apr 5, 2024

1711 West Genesee Street, Syracuse, NY 13204 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Feb 5, 2019: Employee incurs multiple fractures in fall through skylight

On February 5, 2019, Employee #1, employed by a roofing contractor, was engaged in roof repair work at a one-story commercial building. He was on the roof and using a stripping tool to strip shingles when his tool became stuck. The employee lost his balance, fell through the skylight he was standing next to, and struck the concrete surface, a fall height of 22 feet. Emergency services transported the employee to the hospital, where he was admitted and treated for three rib fractures, a fractured pelvis, and a fractured hip.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,273$160Feb 13, 2019Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,273$160Feb 13, 2019Final
Citation 1, item 3b
29 CFR 1926.405(j)(1)(ii) · Job-site wiring
Serious$0$0Feb 13, 2019Final
Citation 1, item 3c
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Feb 13, 2019Final
Citation 1, item 4a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,978$160Feb 13, 2019Final
Citation 1, item 4b
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$0$0Feb 13, 2019Final
Citation 1, item 5
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,842$160Feb 13, 2019Final
Citation 1, item 6
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,842$160Feb 13, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.