OSHA SearchOSHA records by employer

Lanco Scaffolding, Inc.: OSHA inspections and violations

Boston, Massachusetts · All Other Specialty Trade Contractors · NAICS 238990

5inspections
7citation items
$14,174current penalties
Jun 5, 2024last inspection

Since 2003, OSHA inspectors have visited Lanco Scaffolding, Inc. in Massachusetts 5 times.

The most recent inspection opened on Jun 5, 2024 on a referral, in Boston.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $16,709; today they stand at $14,174, 15% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lanco Scaffolding, Inc. averages $3,687 across 2 cited inspections.

Lanco Scaffolding, Inc.: OSHA citation items per year, 2003 to 2024
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

247employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Lanco Scaffolding, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347529521 OPENED JUN 5, 2024Closed

Referral · Partial · Safety · 5 employees at the site · Closed Dec 30, 2024

380 Riverway, Boston, MA 02115 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,839$4,839Oct 22, 2024Final

Inspection 342629375 OPENED SEP 12, 2017Closed

Planned · Partial · Safety · 20 employees at the site · Closed Feb 26, 2018

206 Washington Street, Boston, MA 02109 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$5,070$2,535Sep 27, 2017Final

Inspection 342648136 OPENED JUL 27, 2017Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Jul 27, 2017

1400 Hancock Street, Quincy, MA 02169 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306809229 OPENED NOV 24, 2003Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 8, 2004

179 Longwood Avenue, Boston, MA 02115 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$2,000$2,000May 24, 2004Closed

Inspection 306270570 OPENED AUG 25, 2003Closed

Referral · Complete · Safety · 6 employees at the site · Closed May 6, 2004

39 Main Street, Hatfield, MA 01038 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$1,500$1,500Oct 1, 2003Closed
Citation 1, item 2
29 CFR 1926.451(e)(9)(i) · Scaffolds, general requirements
Serious$300$300Oct 1, 2003Closed
Citation 1, item 3
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$1,500$1,500Oct 1, 2003Closed
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$1,500Oct 1, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.451(e)(9)(i)

(i) The employer shall provide safe means of access for each employee erecting or dismantling a scaffold where the provision of safe access is feasible and does not create a greater hazard. The employer shall have a competent person determine whether it is feasible or would pose a greater hazard to provide, and have employees use a safe means of access. This determination shall be based on site conditions and the type of scaffold being erected or dismantled.

Other all other specialty trade contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.