Landsouth Construction, LLC: OSHA inspections and violations

Lawrenceville, Georgia · Commercial and Institutional Building Construction · NAICS 236220

5inspections
3citation items
$13,471current penalties
Aug 8, 2019last inspection

Landsouth Construction, LLC has 5 OSHA inspections on record in Georgia, the first in 2000.

OSHA's last visit started on Aug 8, 2019 as part of a related case, in Gainesville.

Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $23,799 in penalties. After settlements and reviews the total is $13,471, down 43%.

Most often, OSHA cited 1926.152, flammable liquids (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Landsouth Construction, LLC averages $6,736 over 2 cited inspections in that time.

Landsouth Construction, LLC: OSHA citation items per year, 2000 to 2019
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Landsouth Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Landsouth Construction, LLC at 29 sites in 3 states. Together they've had 46 inspections and $36,913 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 29 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 344218912 OPENED AUG 8, 2019Closed

Unprogrammed related · Complete · Safety · 4 employees at the site · Closed Dec 3, 2019

1000 New Holland Road, Gainesville, GA 30501 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.152(d)(2) · Flammable liquids
Other-than-serious$7,971$3,986Sep 5, 2019Final
Citation 1, item 2
29 CFR 1926.152(e)(4) · Flammable liquids
Other-than-serious$7,971$3,986Sep 5, 2019Final

Inspection 342018876 OPENED JAN 11, 2017Closed

Planned · Complete · Safety · 87 employees at the site · Closed Mar 1, 2017

1760 Lakes Pkwy., Lawrenceville, GA 30043 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341818912 OPENED OCT 4, 2016Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 29, 2016

1760 Lakes Parkway, Lawrenceville, GA 30043 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$7,857$5,499Oct 27, 2016Final

Inspection 305860033 OPENED FEB 25, 2003Closed

Planned · No inspection · Safety · Closed Feb 25, 2003

1500 Preston Blvd, Douglasville, GA 30135 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303381404 OPENED AUG 30, 2000Closed

Referral · Partial · Safety · 3 employees at the site · Closed Aug 30, 2000

Preston Pointe Apartments, Cumming, GA 30040 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(d)(2)

(2) At least one portable fire extinguisher having a rating of not less than 20-B units shall be located not less than 25 feet, nor more than 75 feet, from any flammable liquid storage area located outside.

29 CFR 1926.152(e)(4)

(4) The dispensing units shall be protected against collision damage.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other commercial and institutional building construction employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.