Langston Construction, LLC: OSHA inspections and violations

Lufkin, Texas · Structural Steel and Precast Concrete Contractors · NAICS 238120

3inspections
5citation items
$4,020current penalties
Oct 28, 2015last inspection

Langston Construction, LLC has 3 OSHA inspections on record in Texas, the first in 1997.

OSHA's last visit started on Oct 28, 2015 as a planned inspection, in San Antonio.

Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $6,500 in penalties. After settlements and reviews the total is $4,020, down 38%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Langston Construction, LLC averages $1,920 over 1 cited inspection in that time.

Langston Construction, LLC: OSHA citation items per year, 1997 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Langston Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341021251 OPENED OCT 28, 2015Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jan 22, 2016

9106 Ingram, San Antonio, TX 78245 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,600$960Dec 14, 2015Final
Citation 1, item 2
29 CFR 1926.1060(a)(1) · Ladder and stairway training
Serious$1,600$960Dec 14, 2015Final

Inspection 305467672 OPENED SEP 5, 2003Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 3, 2005

1607 Inwood, Dallas, TX 75247 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,000$600Oct 6, 2003Closed
Citation 1, item 2
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,000$1,200Oct 6, 2003Closed

Inspection 301308086 OPENED MAY 20, 1997Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 23, 1997

3402 Daniel Mccall Drive, Lufkin, TX 75901 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$300$300Jul 3, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)(1)

(1) The employer shall ensure that each employee has been trained by a competent person in the following areas, as applicable:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.