OSHA SearchOSHA records by employer

Lara and Sons Constuction LLC: OSHA inspections and violations

Logan, Utah · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
4citation items
$4,200current penalties
Aug 9, 2024last inspection

OSHA inspectors have visited Lara and Sons Constuction LLC in Utah one time.

It opened on Aug 9, 2024 after an accident, in Logan.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The proposed penalties came to $8,400; today they stand at $4,200, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lara and Sons Constuction LLC averages $4,200 across 1 cited inspection.

Lara and Sons Constuction LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Lara and Sons Constuction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347685240 OPENED AUG 9, 2024Closed

Accident · Partial · Safety · 14 employees at the site · Closed Sep 13, 2024

714 W 400 N, Logan, UT 84321 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,200$2,100Aug 26, 2024Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,200$2,100Aug 26, 2024Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$0$0Aug 26, 2024Final
Citation 2, item 2
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Other-than-serious$0$0Aug 26, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other new multifamily housing construction (except for-sale builders) employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.